756395
21
Zoom out
Zoom in
Previous page
1/28
Next page
EN 20
Operating manual – thermal imaging camera IC085LV / IC125LV
Settings menu
The following submenus can be selected in this menu:
Analysis
Image
System
Analysis submenu
The following settings can be made in this menu:
Designation Function
Global
Param.
Emissivity Set emissivity, value range 0.00 to
1.00
Distance Set distance to object
Ambi. Temp Set ambient temperature
Refl.Temp Set reflected temperature of the
environment
Humidity Set relative humidity of the
environment
Offset Set temperature offset (shift of the
camera's internal calibration curve
around zero)
Background Hide
Show
Reset Reset factory settings
Temp. Range Select temperature range:
-20 °C to +150 °C or 140 °C to
600 °C
Emiss Table List of different emissivities
Comp. Temp. Comparison of a selected
measuring spot with a set
reference temperature
Lens When using an optional
interchangeable lens, enter the
aperture angle of the lens used
(and specified in the menu)
Image submenu
Submenu Settings
Shutter Interval Set shutter interval for IR lens
Quick Launcher Activate or deactivate quick launch
button
Save image only Activate or deactivate Save image only
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Trotec IC085LV at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Trotec IC085LV in the language / languages: English as an attachment in your email.

The manual is 8,46 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Trotec IC085LV

Trotec IC085LV User Manual - German - 28 pages

Trotec IC085LV User Manual - Dutch - 28 pages

Trotec IC085LV User Manual - French - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info