CO₂ air quality data logger BZ30
Diagram control
In the following you will find information regarding the subitems
of the diagram control section(4).
Data graph Data list
Setting the scale format
Data overview
Setting the graph format Undo zoom
[Temperature] [Relative humidity]
ppm [CO2]
°C
%RH
Button Function
Data graph Displays the graph with the recorded
values for CO2, temperature and relative
humidity.
Setting the scale
format
Opens the dialog window for adjusting
the horizontal and vertical scales of the
individual channels.
Data list Changes from the graphic display of the
measured values to a list indicating the
individual measuring points.
Data overview Displays a summary of the gathered
data.
Setting the graph
format
Opens the dialog window for adjusting
the background colour, grid lines and
depiction of the three channels.
Undo zoom Indicates the total view of the data
graph.
Zoom Allows to zoom into sections of the
graph.
Cursor Allows to select individual data points.
Adjusting the data logger settings
Click the icon on the toolbar(2) to open the Data logger
settings dialog window.
Data logger settings
Time settings
Current time
Date format DD/MM/YY
Sampling setting
Sampling rate Second
Recording time 1day 4hours 5minutes 36seconds
OK
Cancel
Starting recording
Automatically Manual
CO2 alarm settings
Limit value alarm
Alarm Value
1. Time settings
The current system time is displayed in the Current time
field.
The date format can be set as year/month/day,
month/day/year or day/month/year.
2. Sampling setting
The Sampling setting field prompts the device to record the
measured values at a certain frequency. In the combo box
on the left, you can enter a specific value for the sampling
rate. From the combo box on the right, you can select the
time unit. The Recording time combo box shows the
maximum recording time (depends on the set sampling
rate).
3. Starting recording
The Manual and Automatic selection options allow for the
user to start data logging immediately after exiting the
setting window (Automatic) or to manually start at a later
point in time by pressing the respective button (Manual).
4. CO2 alarm settings
If the Limit value alarm checkbox is checked, the user can
enter the alarm value (in ppm). If the respective measured
value is beyond the alarm limit, the device triggers an
alarm.
Info
Prior to setting the logger to recording mode, the
logger settings [Data logger settings] must always be
made first! In this process, it is irrelevant whether the
settings are changed or remain the same. All saved
data are permanently deleted when set-up is complete.
To save those data before they are deleted, click
Cancel and then download the data.
Adjusting the scale setting
Click the Set scale format button to adjust the horizontal and
vertical graph scales. The Scale format dialog window opens.
Timescale
Start date and time End date and time
Automatic scale User-defined scale
Selecting a channel
Vertical scale
Unit
Minimum
Maximum
Automatic scale User-defined scale
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Trotec BZ30 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Trotec BZ30 in the language / languages: English as an attachment in your email.

The manual is 2.33 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Trotec BZ30

Trotec BZ30 User Manual - Dutch - 13 pages

Trotec BZ30 Quick start guide - All languages - 7 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info