CO₂ air quality data logger BZ30
Operation
Inserting the battery
Insert the battery into the device before first use. The scope of
delivery includes a 3.7Vbattery. This battery is not intended for
long-term power supply, but merely for bridging short power
interruptions.
Proceed as follows to insert the battery:
1. Push the suspension bracket of the battery compartment
at the rear of the device to the right.
2. Insert the battery into the device with correct polarity(+/-).
3. Close the battery compartment by pushing the bracket on
the battery compartment in the opposite direction.
Connecting the power adapter
Prior to use, connect the device to the mains using the supplied
power adapter.
DC:6V/1A
Start-up
Press the button at the rear of the device for approx. 1second
to switch the device on. The device will then start a warm-up
phase lasting 120seconds.
Setting date and time
Press and hold the Clockbutton for approx. 4seconds to set
time and date. The day indication starts flashing. Press the
button again to switch between year, month, day, hours and
minutes. Press one of the buttons or to increase or
decrease the number flashing on the display. To exit the setting
mode and to save the entered value press the ESCbutton once
you have set the correct date and time.
Info
You can modify the order of day, month and year
within the supplied software. For more detailed
information please refer to the “Using the software”
section.
Hold function
Press the button(hold) to permanently indicate or "freeze"
the displayed values.
Info
In recording mode: Press and hold the / RECbutton
to stop recording.
Alarm function
The device features an alarm function that indicates when a
previously set CO2threshold is exceeded.
Please proceed as follows to enable the alarm function:
1. Press the ALARMbutton.
ðThe alarm function is enabled and the alarm symbol
appears on the display. As soon as the measured value
exceeds the previously set limit value, an acoustic alarm
signal will be emitted and the buttons below the display
start to flash in red.
2. Press the button again to exit or disable the alarm mode.
Setting the limit value for the alarm function
Please proceed as follows to set a new limit value:
1. Press and hold the ALARMbutton for approx. 5seconds.
ðThe previously set limit value appears on the display
and the displayed alarm symbol flashes.
2. Press or to increase or reduce the decrease the
displayed number.
3. Then you can press the ESCbutton to exit the mode and to
adopt the set value or to change the limit values for the
feel-good indication .
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Trotec BZ30 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Trotec BZ30 in the language / languages: English as an attachment in your email.

The manual is 2.33 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Trotec BZ30

Trotec BZ30 User Manual - Dutch - 13 pages

Trotec BZ30 Quick start guide - All languages - 7 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info