EN 8
Operating manual – humidifier B 5 E
Controlling humidification
The desired room humidity can be set to 40%, 50%, 60% or
OL (continuous humidification regardless of the room humidity).
1. Press the Humidity button(26) until the desired room
humidity is displayed.
ð The desired room humidity flashes on the segment
display(17) for approx.5s.
ð Then, the current relative room humidity is shown on
the segment display(17) again.
ð The desired relative room humidity is set.
Setting the nebulizer intensity
The nebulizer intensity can be set in manual humidification
mode. The default setting is level2.
The nebulizer intensity can be set to 3levels:
level1 = low nebulizer intensity
level2 = medium nebulizer intensity
level3 = high nebulizer intensity
1. Press the Mist button(31).
ð The current nebulizer intensity flashes on the nebulizer
intensity indication(16).
2. Press the Mist button(31) again until the desired nebulizer
intensity is set.
3. Wait until the nebulizer intensity indication(16) stops
flashing and dynamically indicates operation again.
ð The desired nebulizer intensity is set.
Setting the operating mode
Manual humidification
The device always starts in this operating mode. The current
room humidity and nebulizer intensity are shown on the display.
The desired relative room humidity can be adjusted at any time
in this operating mode. The setting options are 40%, 50%,
60% or OL (continuous humidification regardless of the room
humidity).
The nebulizer intensity can be adjusted at any time in this
operating mode.
If the current relative room humidity is lower than the
desired relative room humidity, the device humidifies the
air with the selected nebulizer intensity.
If the current relative room humidity is equal to or higher
than the desired relative room humidity, the device
humidifies the air at nebulizer intensity level 1.
If OL is selected, the device humidifies the air with the
selected nebulizer intensity regardless of the current
relative room humidity.
Automatic mode
The device humidifies the air constantly and regardless of the
relative room humidity.
The desired relative room humidity and the nebulizer intensity
cannot be adjusted in this operating mode.
In automatic mode, the device operates with the following
settings:
If the current relative room humidity is equal to or higher
than 60%, the device humidifies the air at nebulizer
intensity level 1.
If the current relative room humidity is between 40% and
60%, the device humidifies the air at nebulizer intensity
level 2.
If the current relative room humidity is below 40 %, the
device humidifies the air at nebulizer intensity level 3.
1. Press the Auto button(30).
ð The AUTOindication(23) is displayed.
ð The device operates in automatic mode.
2. Press the Sleep button(29) to switch over to night mode,
or the Autobutton(30) to switch over to baby mode.
Baby mode
The device humidifies the air constantly to create a room
humidity level that is pleasant for babies.
The desired relative room humidity and the nebulizer intensity
cannot be adjusted in this operating mode.
In baby mode, the device operates with the following settings:
If the current relative room humidity is higher than 60 %,
the device humidifies the air at nebulizer intensity level 1.
If the current relative room humidity is between 55% and
60%, the device humidifies the air at nebulizer intensity
level 2.
If the current relative room humidity is below 55 %, the
device humidifies the air at nebulizer intensity level 3.
1. Press the Auto button(30) until the BABY indication(20)
appears on the display.
ð The device operates in baby mode.
2. Press the Sleep button(29) to switch over to night mode,
or the Autobutton(30) to switch over to automatic mode.
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Trotec B5E at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Trotec B5E in the language / languages: English as an attachment in your email.

The manual is 1,45 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Trotec B5E

Trotec B5E User Manual - German - 16 pages

Trotec B5E User Manual - Dutch - 18 pages

Trotec B5E User Manual - French - 18 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info