24. Correcting faults
If your device is not working properly, please check the following points:
Problem Cause What to do?
No functionality Device not connected Check mains connector
Water tank symbol lights red No water Fill with water
Device does not start up Humidity is higher than the desired hu-
midity set „Enter“ was not pressed when
altering the humidity value or blower stage
Water indicator copper electrodes fouled
If appropriate change the set
value After changing the value
always press „Enter“ on the
remote control
Clean copper electrodes
Device runs but does not
take in any water
Pump hoses not correctly fitted or fouled
Lime conversion cartridge clogged 1)
Pump defect
Clean pump hoses or fit correctly
Clean or bore out cartridge
Replace pump
Water channel overflows Outflow holes are clogged Clean water distribution and
outflow holes
Water is escaping from the
device
Filter is used
Filter is not correctly installed
Renew filter
Check the filter seating
Water degermination moni-
tor lamp does not light 1)
UV-source defect Replace UV-source
Device does not respond to
the remote control
Battery discharged or incorrectly installed
Distance between remote control and
device too great
Check battery and replace ; note +/-
Reduce distance
Automatic water feed no
longer replenishes water 2)
Safety pressure hose defect – Water
feed is automatically stopped
Replace hose
Water feed runs conti-
nuously 3)
Water feed floater stuck Remove fouling in the feed, replace
float
Water monitor outputs acou-
stic signal 3)
Water has escaped Check cause. Separate the feeding
line to the water monitor from the
mains for a few seconds
Radio transmitter outputs
acoustic signal
Batteries in transmitter are discharged Replace batteries
Newly fitted batteries are
not working
Battery were incorrectly fitted
(polarity not observed)
Fit new batteries
1) Only for special UV-technology version with lime conversion cartridge
2) Only for special automatic water feed version with safety pressure hose
3) Only for special electronic water monitor version
37


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Trotec B500 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Trotec B500 in the language / languages: English, German, French as an attachment in your email.

The manual is 5,8 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info