OPERATING PROBLEMS
START-UP
Compressor does not start even though the desired temperature is lower than the
temperature in the room.
1. Check the wall socket by plugging in any type of electrical device, and male sure that the
on/off button in pressed.
2. Press the TEST button and check that the two red and green indicator lights light up (in the
standby status).
3. If the compressor still does not start after steps 1 and 2, contact your dealer.
Compressor does not stop
Place your hand on the condenser (metal screen at the back of your cabinet) to check its
temperature contact your dealer if cold.
If the condenser is hot, set the cold temperature as high as possible (as far as it will go
clockwise) and make sure that the cold circuit operation indicator goes off, if the
compressor does not stop, unplug the cabinet and contact your dealer.
DURING OPERATION
A digital tube display indicate a temperature below the temperature you set.
1. check the temperature set-points
2. check that the red hot circuit operation indicator light is on.
3. Press the TEST button, and check that the two red and green indicator lights on the right
side of the panel are on. If either step 1 or 3 is incorrect contact your dealer.
Digital tube display indicates a temperature above the temperature you set.
1. check the temperature set-points.
2. Check that the green cold circuit operation indicator light is on.
3. Press the TEST button, and check that the two red and greed indicator lights on the right
side of the panel are on, if either step 2 or 3 is incorrect contact your dealer.
Contact your dealer, if after adjusting set-points and testing hot and cold circuit indicator lights
either of the two problems above are not corrected.
Note: the refrigeration unit must only be serviced by a refrigeration technician, who
must check the circuit for leaks before putting back into service, any servicing of the
electrical circuit must only be performed by an electrician.
NB: whatever the case, if your cabinet does not seem to be operating normally, unplug
it and call your dealer.
10
44


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Tristar WR-1995 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Tristar WR-1995 in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 2,5 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info