637494
7
Zoom out
Zoom in
Previous page
1/72
Next page
7
EN
OPERATION
Timer setting
Timer o: When the air conditioner is running, press the timer button,
the timer LED lamp is on, and the display will blink. Use the UP and
DOWN buttons to adjust time from 0.5h to 24h. When the set time
expires, the air conditioner turns o automatically.
Timer on: When the air conditioner is in standby mode, press the timer
button, the timer LED lamp is on, and the display will blink. Use the UP
and DOWN buttons to adjust time from 0.5h to 24h.
During this setting procedure, the operating modes after start can
be selected, if the cool mode is selected, the set temperature can be
adjusted simultaneously. After the set time expires, the air conditioner
starts automatically and runs in the selected operating mode.
Change of the set time
You can press TIMER once In the running process of the timer, the remain-
ing time will be displayed. Press the UP and DOWN buttons to increase/
decrease the time. If you press the TIMER button again during blinking, the
set time will be cancelled, namely timer quits.
COOL mode
!!!Attention: if the air conditioner is restarted immediately after shutdown
in the COOL mode, it will take 3 minutes before the cooling process will
start.!!!
Press the MODE button to select the COOL mode.
Press the UP or DOWN button to set the desired temperature in a range
of 18~30
o
C (64-86
o
F).
Press the SPEED button to select the desired fan speed.
After selecting COOL mode, press the SLEEP button on the
remote control to enter the SLEEP mode. The speed level will turn
automatically in the lowest mode and the air conditionor will turn o
automatically in approximate 7h.
Press the SWING button to activate the swing function.
DEHUMIDIFY mode
Make sure the exhaust pipe is not installed.
Press the MODE button to select the DEHUMIDIFY mode.
Temperature and speed are not adjustable.
Press the SWING button to activate the swing function.
FAN mode
Press the MODE button to select the FAN mode.
Press the SPEED button to select the desired fan speed. In this mode
press SPEED for “5 seconds” to run the internal dry function, i.e. both
upper and lower fans work simultaneously. Press SPEED for another “5s”
to cancel the internal dry function. Make sure the exhaust pipe is not
installed during this mode.
During the fan mode the temperature is not adjustable.
Press the SWING button to activate the swing function.
Cautions:
When water full indication light comes on, the air conditioner will stop
work, you should drain the water like described further in the manual.
After drainage the air conditioner will start automatically.
If your room faces the sun directly, please close the curtains.
DRAINAGE OPERATION FIGURE 8.
When water full indication light comes on, the air conditioner will stop
work, you should drain the water.
Place the air conditioner on a place where you can drain the water
directly (such as toilet or sewer).
Unscrew the nut and pull out the plug. Install the plug and nut before
use.
Air conditioner
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Tristar AC-5522 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Tristar AC-5522 in the language / languages: English, German, Dutch, French, Italian, Polish, Portuguese, Swedish, Spanish as an attachment in your email.

The manual is 2,06 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info