WATER DRAINAGE
Manual(Figure 12)
Once the unit shuts down upon full water, turn off the unit and unplug
the power plug.
Put a tray for the water below the water outlet at the back of the unit.
Screw off the drain cap, unplug the water plug and water will flow out.
Tilt the unit slightly backward when draining.
If the water tray is full before the unit is empty block the water outlet
with the water plug as soon as possible to prevent the water from
flowing onto the ground or carpet.
Once the water is fully drained, insert the water plug and screw on the
water cap tightly.
Turn on the unit only after the water plug and drain cap are installed properly;
otherwise, the condensate of the unit will flow onto the ground or carpet.
Continuous drain (Figure 13 + 14)
1. Screw off the water cap insert a 13mm PVC drain hose 8mm-10mm into
the water outlet.
2. Connect the drain hose to the toilet or outdoor.
3. When operating in the heating mode, adopt continuous drain; other-
wise, the unit may shut down due to full water.
4. Put the drain hose in an inaccessible place at a height not above the
water outlet and keep the drain hose free from flexure.
Maintenance and Servicing
Prior to maintenance and servicing of the unit, turn off the power and
unplug the plug.
Clean the surface of the unit with wet soft cloth. Do not use chemical
solvents such as alcohol and gasoline; otherwise, the surface of the air-
conditioner may be damaged.
Clean the filters once every two weeks. If the filter frame and filter are
clogged with dust, the function of the air-conditioner may decrease
Take out the filter frame gently in the direction shown by the arrow (as
shown in Figure 15 + 16).
Put the filters into warm water (about 40°C) to which neutral cleaner is
added for cleaning and then dry them in the shade.
Make sure the filters are completely dry before placing them back in the
unit.
TROUBLESHOOTING
Problem/fault
indication
Cause Remedy
The air-conditioner
does not work
No power
Full water indicator
illuminates?
Ambient temperature too
low ?
The room temperature is lower
than the set temperature in the
cooling mode.
Connect the unit to a live
socket and turn it on.
Drain the water stored in the
unit.
It is recommended that this
unit be operated at 10-35°C.
Change the set temperature
Bad cooling or heating
effects
There is direct sunlight
The doors and windows are
open, the room is crowded or
there are other heat sources
in the cooling mode
Filter mesh very dirty
Air inlet or air outlet clogged
Draw the curtain on.
Close the door and window
and add new air-conditioners
Clean or replace the filter
mesh
Remove the obstruction
Large noise Air-conditioner not put on a
flat surface
Put the air-conditioner in a flat
and firm place (may reduce
noise)
The compressor does
not work
Initiation of overheat
protection.
Wait 3 minutes until the
temperature decreases and
then turn on the unit
The remote control
does not work
Too long a distance
The remote control does not
point toward the receiving
head of the remote control
The batteries have no
electricity
Bring the remote control
close to the air-conditioner
and ensure that the remote
control points toward the
receiving head of the remote
control.
Replace the batteries
Display E1 Pipe temperature sensor
failure
Check the pipe temperature
sensor and related circuits
Display E2 Room temperature sensor
failure
Check the room temperature
sensor and related circuits
Display E4 Anti-freeze protection Restore the functions
automatically once defrozen.
Full water indicator
illuminates
The water in the baseplate
of the unit reaches the full
water level
Drain the water in the
baseplate.
Instruction manual
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Tristar AC-5517 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Tristar AC-5517 in the language / languages: English, German, Dutch, French, Italian, Polish, Portuguese, Swedish, Spanish as an attachment in your email.

The manual is 1,28 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info