664771
8
Zoom out
Zoom in
Previous page
1/32
Next page
JetStream Gigabit L2 Managed Switch
04
Introduction
SFP Port
Designed to install the SFP module. T2600G-52TS features 4 individual SFP ports and supports
1000M SFP module connection only.
The front panel of The T2600G-28MPS is shown as the following figure.
Figure 1-4 Front Panel of T2600G-28MPS
10/100/1000Mbps
RJ45 Port
LEDs Console
(USB)
Console
(RJ45)
SFP Port
T2600G-28MPS has an LED mode switch button which is for switching the LED status indication.
When the Speed LED is on, the port LED is indicating the data transmission rate. When the PoE LED
is on, the port LED is indicating the power supply status. By default the Speed LED is on. Pressing
the mode switch button, the Speed LED will turn off and the PoE LED will light up. Then the PoE LED
will turn off after being on for 60 seconds and the Speed LED will light up again.
When the Speed LED is on, the port LED is indicating the data transmission status.
LEDs
LED Status Indication
PWR
On The switch is powered on.
Off The switch is powered off or power supply is abnormal.
Flashing Power supply is abnormal.
SYS
Flashing The switch works properly.
On/Off The switch works improperly.
FAN
Green All the fans work properly.
Yellow Not all the fans work properly.
Off The switch works improperly.
Speed or
PoE (Port
1-24
Green
On A 1000Mbps device is linked to the corresponding port, but no activity.
Flashing
A 1000Mbps device is linked to the corresponding port and data is
being transmitted or received.
Yellow
On
A 10/100Mbps device is linked to the corresponding port, but no
activity.
Flashing
A 10/100Mbps device is linked to the corresponding port and data is
being transmitted or received.
Off No device is linked to the corresponding SFP port but no activity.
1000Base-X
(Port 25-28)
On
There is a device linked to the corresponding port.
Flashing
The corresponding SFP port is transmitting or receiving data.
Off There is no device linked to the corresponding SFP port.
When the PoE LED is on, the port LED is indicating the power supply status.
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for TP-LINK T2600G-18TS-TL-SG3216 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of TP-LINK T2600G-18TS-TL-SG3216 in the language / languages: English as an attachment in your email.

The manual is 3,08 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info