714420
761
Zoom out
Zoom in
Previous page
1/771
Next page
Configuration Guide 738
Configuring SNMP & RMON Configuration Example
Switch(config)#rmon history 2 interface gigabitEthernet 1/0/2 interval 100 owner
monitor buckets 50
3) Create two event entries named admin, which is the SNMP user name. Set entry 1 as
the Notify type and its description as “rising notify”. Set entry 2 as the Log type and its
description as “falling log”. Set the owner of them as monitor.
Switch(config)#rmon event 1 user admin description rising-notify type notify owner
monitor
Switch(config)#rmon event 2 user admin description falling-log type log owner monitor
4) Create two alarm entries. For entry 1, set the alarm variable as BPackets, associated
statistics entry ID as 1 (bound to port 1/0/1), the sample type as Absolute, the rising
threshold as 3000, the associated rising event entry ID as 1 (Notify type), the falling
threshold as 2000, the associated falling event entry ID as 2 (the log type), the alarm
type as all, the interval as 10 seconds, and the owner name as monitor. For entry
2, set the associated statistics entry ID as 2 (bound to port 1/0/2), while all other
configurations are the same as those of entry 1.
Switch(config)#rmon alarm 1 stats-index 1 alarm-variable bpkt s-type absolute rising-
threshold 3000 rising-event-index 1 falling-threshold 2000 falling-event-index 2 a-type
all interval 10 owner monitor
Switch(config)#rmon alarm 2 stats-index 2 alarm-variable bpkt s-type absolute rising-
threshold 3000 rising-event-index 1 falling-threshold 2000 falling-event-index 2 a-type
all interval 10 owner monitor
Verify the Configurations
Verify global SNMP configurations:
Switch(config)#show snmp-server
SNMP agent is enabled.
0 SNMP packets input
0 Bad SNMP version errors
0 Unknown community name
0 Illegal operation for community name supplied
0 Encoding errors
0 Number of requested variables
0 Number of altered variables
0 Get-request PDUs
0 Get-next PDUs
0 Set-request PDUs
0 SNMP packets output
761


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for TP-LINK T1600G-52TS (TL-SG2452) at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of TP-LINK T1600G-52TS (TL-SG2452) in the language / languages: English as an attachment in your email.

The manual is 7,29 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info