Configuring SNMP & RMON RMON Configurations
Configuration Guide
723
Variable Set the alarm variable to be monitored. The switch will monitor the specified
variable in sample intervals and act in the set way when the alarm is triggered.
The default variable is RecBytes.
RecBytes: Total received bytes.
RecPackets: Total received packets.
BPackets: Total broadcast packets.
MPackets: Total multicast packets.
CRC&Align ERR: Packets that range from 64 to 1518 bytes and contain FCS
Error or Alignment Error.
Undersize: Packets that are smaller than 64 bytes.
Oversize: Packets that are larger than 1518 bytes.
Jabbers: Packets that are sent when port collisions occur.
Collisions: Collision times in the network segment.
64, 65-127, 128-255, 256-511, 512-1023, 1024-10240: Total packets of the
specified size.
Statistics Associate the alarm entry with a statistics entry. Then the switch monitors the
specified variable of the statistics entry.
2) Set the sample type, the rising and falling threshold, the corresponding event action,
and the alarm type of the entry.
Sample Type Set the sampling method of the specified variable; the default is absolute.
Absolute: Compare the sampling value against the preset threshold.
Delta: The switch obtains the difference between the sampling values of the
current interval and the previous interval, and then compares the difference
against the preset threshold.
Rising Threshold Set the rising threshold of the variable. When the sampled value exceeds the
threshold, the system will trigger the corresponding Rising Event. The ranges
are from 1 to 2147483647; the default is 100.
Rising Event Specify the index of the event that will be triggered when the sampled value
exceeds the preset threshold.
Falling Threshold Set the falling threshold of the variable. When the sampled value is below
the threshold, the system will trigger the corresponding Falling Event. The
ranges are from 1 to 2147483647; the default is 100.
Falling Event Specify the index of the event that will be triggered when the sampled value is
below the preset threshold.
746


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for TP-LINK T1600G-28PS (TL-SG2424P) at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of TP-LINK T1600G-28PS (TL-SG2424P) in the language / languages: English as an attachment in your email.

The manual is 7,29 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info