727656
13
Zoom out
Zoom in
Previous page
1/88
Next page
7
ENGLISH
MALFUNCTION ANALYSIS
Malfunction code
H8 Tank is full of water. 1. Pour out the water inside tank.
2. If “H8” still exists, please contact
professional person to maintain
the unit.
F1 Malfunction of ambient
temperature sensor.
Please contact professional person
to deal with it.
F2 Malfunction of evapora-
tor temperature sensor.
Please contact professional person
to deal with it.
F0 1. Refrigerant is leaking.
2. System is blocked.
Please contact professional person
to deal with it.
H3 Overload protection for
compressor.
1. If ambient temperature is too
high, power off the unit and then
energize it for operation after the
ambient temperature drops to be-
low 35°.
2. Check if the evaporator and con-
denser are blocked by some ob-
jects. If yes, take away the ob-
jects, power off the unit and then
energize it for operation.
3. If the malfunction still occur,
please contact our after-sales ser-
vice center.
E8 Overload malfunction.
F4 Outdoor tube
temperature
sensor is open/
short-circuited.
11. SPECIFICATIONS
MODEL TAD-220E TAD-226E TAD-229E TAD-235E
POWER SOURCE
Single Phase
220~240 V,
50 Hz
Single Phase
220~240 V,
50 Hz
Single Phase
220~240 V,
50 Hz
Single Phase
220~240 V,
50 Hz
COOLING
CAPACITY
2,1 kW
(7.165 BTU)
2,6 kW
(8.870 BTU)
2,9 kW
(9.894,8 BTU)
3,5 kW
(11.942 BTU)
COOLING POWER
INPUT
805 W 1.000 W 935 W 1.345 W
HEATING
CAPACITY
3,3 kW
(11.260 BTU)
HEATING POWER
INPUT
1.175 W
EE Class / EER* A / 2,60 A / 2,60 A+ / 3,10 A / 2,60
EE Class / COP* A+ / 2,80
POWER
CONSUMPTION IN
STANDBY MODE
0,5 W 0,5 W 0,5 W 0,5 W
DEHUMIDIFYING
CAPACITY
1,0 L/h 1,43 L/h 1,60 L/h 1,80 L/h
OPERATING
CURRENT
3,5 A 4,4 A 4,1 A
5,8 A / 5,1 A
(Cooling/
Heating)
AIR FLOW (MAX.) 320 m
3
/h 320 m
3
/h 360 m
3
/h 360 m
3
/h
FOR ROOMS UP
TO
10 - 16 m
2
10 - 16 m
2
15 - 22 m
2
15 - 22 m
2
OPERATING
TEMP. RANGE
16~35°C 16~35°C 16~35°C
16°C~35°C /
10°C~ 27°C
(Cooling /
Heating)
SOUND POWER
LEVEL
63 dB 64 dB 64 dB 65 dB
UNIT PROTECTION IPX0 IPX0 IPX0 IPX0
FUSE RATING 3,15 A 3,15 A 3,15 A 3,15 A
DIMENTIONS
(W×H×D)
315×770×
395 mm
315×770×
395 mm
390×820×
405 mm
390×820×
405 mm
WEIGHT 24,5 kg 27,0 kg 36,0 kg 36,5 kg
COMPRESSOR ROTARY ROTARY ROTARY ROTARY
REFRIGERANT
R290 / 0,16 kg R290 / 0,22 kg R290 / 0,30 kg R290 / 0,30 kg
GWP 3 3 3 3
*Confirm to EN-14511: 2018
NOTE: Cooling air capacity will vary according to temperature and
humidity of the room.
(For TAD-229E)
Frequency band(s) in which the radio equipment operates:
2400MHz-2483.5MHz
Maximum radio-frequency power transmitted in the frequency
band(s) in which the radio equipment operates: 20dBm
12. VENTING KIT ACCESSORIES
If the unit is to be used exclusively in one space, the cooling efficien-
cy will be enhanced by using the following venting kit accessories.
USING EXHAUST DUCT SET (Fig. H)
1. Prepare the below accessory.
H1 Exhaust duct hose adapter nozzle (Fix to unit)
H2 Exhaust duct hose
H3 Exhaust nozzle (upper) + Exhaust nozzle (lower)
2. To fix the Exhaust nozzle (upper) and the Exhaust nozzle (low-
er) together, press the clasp forcibly into the groove. (Fig. H4)
3. Insert one end of exhaust duct hose (flexible tube) (H2) into
exhaust duct hose adapter nozzle (H1) by turning it counter
clockwise. And install exhaust nozzle (upper + lower) (H3) into
another side of exhaust duct hose. (Fig. H5)
4. Face the side with “TOP” upwards. Insert exhaust duct hose
adapter nozzle into the groove of exhaust outlet until you hear
a sound. (Fig. H6)
5. Place the exhaust hose outdoors. (Fig. H7)
NOTE: Place the unit as close as possible to the window or
door. (H5, H6, H7)
13. Specialist’s Manual
Aptitude requirement for maintenance man(repairs should be do-
ne only be specialists).
a. All the work men who are engaging in the refrigeration system
should bear the valid certification awarded by the authoritative
organization and the qualification for dealing with the refrigera-
tion system recognized by this industry.
b. It can only be repaired by the method suggested by the equip-
ment’s manufacturer.
If it needs other technician to maintain and repair the appliance,
they should be supervised by the person who bears the qualifi-
cation for using the flammable refrigerant.
Safety preparation work before installation
The safety must be inspected before maintaining the appliances
with the flammable refrigerant for reducing the flammable hazard
to the lowest.
Work shall be undertaken under a controlled procedure so as to
minimise the risk of a flammable gas or vapour being present while
the work is being performed.
Detection of flammable refrigerants
Under no circumstances shall potential sources of ignition be used
in the searching for or detection of refrigerant leaks. A halide torch
(or any other detector using a naked flame) shall not be used.
Environment checking
All maintenance staff and others working in the local area shall
be instructed on the nature of work being carried out. Work in
confined spaces shall be avoided. The area around the work-
space shall be sectioned off. Ensure that the conditions within
the area have been made safe by control of flammable material.
The area shall be checked with an appropriate refrigerant detec-
tor prior to and during work, to ensure the technician is aware of
potentially toxic or flammable atmospheres.
Ensure that the leak detection equipment being used is suitable
for use with all applicable refrigerants, i.e. non-sparking, ade-
quately sealed or intrinsically safe.
No person carrying out work in relation to a refrigeration system
which involves exposing any pipe work shall use any sources of
ignition in such a manner that it may lead to the risk of fire or
explosion. All possible ignition sources, including cigarette
smoking, should be kept sufficiently far away from the site of in-
stallation, repairing, removing and disposal, during which refrig-
erant can possibly be released to the surrounding space.
Prior to work taking place, the area around the equipment is to
be surveyed to make sure that there are no flammable hazards
or ignition risks. “No Smoking” signs shall be displayed.
If any hot work is to be conducted on the refrigeration equip-
ment or any associated parts, appropriate fire extinguishing
equipment shall be available to hand. Have a dry powder or CO
2
fire extinguisher adjacent to the charging area.
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Toyotomi TAD-235E at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Toyotomi TAD-235E in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Spanish as an attachment in your email.

The manual is 30,61 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info