728853
11
Zoom out
Zoom in
Previous page
1/138
Next page
11 GB
Turn of the fluorescent lamp and try again
If any of the following cases occur, turn off the unit, pull out the plug from the socket and contact the authorized service of
DELTA DOMESTIC APPLIANCES S.A. 210 5386490
CAUTION
In case any of the following cases occur, please turn off the unit, pull out the plug from the
socket and contact the authorized service for repair.
Power cord has been overheated or damaged.
Unusual sound is heard during operation.
Circuit breaker often shuts down.
Burning smell comes out of the air conditioner.
There is a leakage from the indoor unit.
DO NOT repair or re-install the air conditioner by yourself.
In case the air conditioner continues to work under unusual conditions, it might cause
malfunction, electric shock, fire or injury.
PARTS NAME
There is sound of running
water during operation
During turning on or turning off the air conditioner, or when compressor stops and
starts again, the sound of running water may be heard from the indoor unit
This is the sound of refrigerant flow and it is normal
During turning on or turning
off the air conditioner there is
a cracking sound
During turning on or turning off the air conditioner you may hear a cracking sound
from the indoor unit
Due to the temperature change, contraction / expansion is caused on the plastic
parts of the air conditioner. This is normal
Indoor unit makes abnormal
sound
During turning on or turning off the air conditioner the sound of compressor or fan is
heard
When defrost function starts a different sound is heard
Flow of refrigerant changes and the different sound is normal
A lot of dust is accumulated on filters
Clean the air filters
During TURBO operation the sound is a little bit louder
This is normal
Water drops are over the
surface of the indoor unit
When ambient humidity is high, water drops will be accumulated around the air
outlet or the panel
This is a normal physics phenomenon
Prolonged cooling run in open space produces water drops
Close the doors and windows
The angle of the louver blades is too small
Regulate the angle of the louver blades so the air flow can run freely
During Cooling operation,
indoor unit outlet sometimes
will blow out mist
When the indoor temperature and humidity are high, it happens sometimes
This happens because the indoor air is cooled rapidly. After it runs form some time,
the indoor temperature and humidity will be reduced, and the mist will disappear.
Air conditioner stopped
suddenly to operate
There is interference, like thunder or wireless devices etc
Disconnect from power. Reconnect to power and operate again the air conditioner
Indoor unit does not accept
remote controllers signal
or remote controller does
not work
There is significant interference (e.g. static electricity, constant voltage)
Turn off the air conditioner, pull out the plug from outlet. Wait 3 minutes then put the
plug to the outlet and restart the function of the air conditioner
Remote controller is out of range
The distance between signal center and receiving window should be no more than
8m
There are obstacles between signal center and window receiver
Remove obstacles
Signal center of remote controller cannot communicate with window receiver of the
indoor unit
Choose the right angle where signal center of remote controller can communicate
with window receiver of indoor unit
The display on remote controller is fuzzy or there is no display at all
Check the batteries. If their power is low, replace them
No display on remote controller
Check if the remote controller is damaged. If yes, please replace it
There is fluorescent lamp in the room
Take remote controller closer to the window receive of indoor unit
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Toyotomi Noboru NTN-NTG-935R32 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Toyotomi Noboru NTN-NTG-935R32 in the language / languages: English, Italian, Spanish as an attachment in your email.

The manual is 11,5 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info