TROUBLESHOOTING
Should problems arise during operation or ignition, use this chart to determine the cause and
the proper steps to take. Be sure to unplug heater and allow to cool completely before taking
corrective measures.
PROBLEM CAUSE SOLUTION
POWER LAMP FAILS
TO TURN ON
NO IGNITION
ODOR
EXTINGUISHED
AFTER IGNITION
POOR COMBUSTION/
NOISY COMBUSTION
Disconnected power plug
Incorrect wiring
Circuit board malfunction
Out of fuel
Clogged air filter
Use of inferior kerosene
(paraffin)
Incorrect wiring
Circuit board, ignition heater
or fuel pump malfunction
Clogged air filter
Spilled kerosene (paraffin)
Use of inferior kerosene
(paraffin)
Excessive room temperature
Oxygen shortage in room
Tip-over switch activated
Water in fuel acceptance
fitting
Out of fuel
Flame sensor or fuel pump
malfunction
High limit switch activated
Clogged air filter
Loose screws or incorrect
assembly
Incorrect wiring
Circuit board or fuel pump
malfunction
Altitude too high
Plug into 230V AC outlet.
Consult your dealer.
Consult your dealer.
Refuel
Clean air filter.
Remove fuel and refuel using
fresh, clear kerosene (paraffin).
Consult your dealer.
Consult your dealer.
Clean air filter
Wipe off any kerosene (paraffin)
spills from fuel sub tank, remov-
able fuel tank and drip tray.
Remove fuel and refuel
using fresh, water-clear
kerosene (paraffin).
Allow room to cool.
Open doors and windows to
ventilate room thoroughly.
Reignite.
Remove fuel and refuel using
fresh, water-clear kerosene
(paraffin).
Refuel
Consult your dealer.
Clean circulation fan cover,
remove any obstructions.
Clean air filter.
Consult your dealer.
Consult your dealer.
Consult your dealer.
Consult your dealer.
If the corrective measures outlined above do not solve the problem, please consult your dealer.
LC-32F (GB) 12.9.3 11:39 AM ページ 12
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Toyotomi LC-32F at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Toyotomi LC-32F in the language / languages: English as an attachment in your email.

The manual is 0,98 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info