5 Select the digital (DVB) / analogue (ATV) mode
or external input (AV1/AV2) using [K \ L], then
press [B].
6 Select the channel number to record using
[K \ L], then press [B].
7 Select the recording media (“HDD” or “DVD”)
using [K \ L], then press [B].
8 Select the recording mode using [K \ L], then
press [B].
Refer to “Recording Mode” on page 28.
Select “STTL” to “ON” or “OFF” using [K \ L].
If you set “STTL” to “ON”, subtitle will be recorded too.
When analogue channel is selected, “VPS/PDC” will be
displayed instead of “STTL”.
Select “VPS/PDC” to “ON” or “OFF” using
[K \ L].
Refer to “VPS (Video Programme System) / PDC
(Programme Delivery Control)” on this page.
When DVB channel is selected, “STTL” will be displayed
instead of “VPS/PDC”.
VPS/PDC system is only available for HDD.
VPS/PDC system is not available for “Daily” and “M-F”
timer programme.
10 Press [ENTER\OK] when all information
required is entered.
Your programme setting is stored.
To set another programme, repeat steps
2 to 10.
To exit, press [TIMER PROG.].
When 2 or more programmes are overlapped, “Timer
programme overlapped” appears, and the overlapped
programme will be displayed in blue. To correct the timer
programme, refer to “Checking, Cancelling or Correcting
the Timer Programming Information” on this page.
The icon will appear on the front panel display.
Note
If you have not set the clock, the clock setting window will
appear instead of the Timer Programming list. Continue
from “Clock Setting” on page 71 before programming the
timer.
•Press [K \ L] to move the cursor in “Timer Programming”
list.
If you have a timer programme with VPS/PDC function, and
if you are watching different channel from the timer
programme, confirmation message to change the channel
will appear 15 minutes before the programme starts (the
message will also re-appear 30 seconds before the
programme starts). The channel will automatically be
changed to the programmed channel 15 seconds before the
programme starts.
Alternate recording (DVD only)...
If there is no recordable disc in the unit, if the disc does not
have enough space to complete the recording, or if the
material is “copy-once” programme and prohibited to be
recorded on a DVD in the unit, the unit will detect it and
automatically record to the HDD even when DVD is selected
as the recording media. If the available space on the HDD is
less than that of DVD, the unit will not perform the alternate
recording. This feature is available only for timer recording.
Not available for one-touch timer recording.
The Video Programme System (VPS) or Programme Delivery
Control (PDC) assures that the TV programmes you have
programmed for timer recording are recorded exactly from
beginning to end, even if the actual broadcasting time differs
from the scheduled time due to a delayed start or extension of
the programme duration. Furthermore, if a programme is
interrupted, the recording will also be interrupted
automatically and resumed when the programme starts again.
If the VPS/PDC signal drops out because the broadcast signal
is weak, or if a broadcasting station does not transmit a
regular VPS/PDC signal, the timer recording is performed in
normal mode (without VPS/PDC) even if it was programmed
for VPS/PDC. If the starting time of the VPS/PDC timer
recording is between 0:00 and 3:59 on a given day, the VPS/
PDC function will operate from 20:00 on the previous day to
4:00 on the next day. If the starting time of the VPS/PDC timer
recording is between 4:00 and 23:59 on a given day, the VPS/
PDC function will operate from 0:00 on the given day to 4:00
on the next day. This means that if the relevant programme is
broadcasted within this period, it is recorded correctly. If the
timer is not programmed correctly, the incorrect timer setting
stays in effect unless you cancel it. To cancel an incorrect
timer setting, refer to “Checking, Cancelling or Correcting the
Timer Programming Information” on this page.
Note
This feature is only available for analogue channels.
1 Press [TIMER PROG.].
2 A) To delete the timer programme:
1) Select the programme you want to delete using
[K \ L], then press [ENTER\OK].
2) Select “Delete” using [K \ L], then press
[ENTER\OK].
Confirmation window will appear.
3) Select “Yes” using [K \ L], then press [ENTER\OK].
B) To correct the timer programme:
1) Select the programme you want to correct using
[K \ L], then press [ENTER\OK].
2) Select “Programme Change” using [K \ L], then press
[ENTER\OK].
3) Correct the timer programme by using [K \ L \ { \ B],
then press [ENTER\OK].
3 Press [TIMER PROG.] to exit.
To check the timer programming in progress
Press [TIMER PROG.].
9 For DVB channel recording:
For analogue channel recording:
1/1
03/120:00
06/12
07/12
07/12
7:00
9:00
17:00
9:00
9:30
18:00
DVB 18
DVB 190
1 TF1
Timer Programming
Date Start End CH
New Programme
STTL
VPS/PDC
THU
VPS (Video Programme System) / PDC
(Programme Delivery Control)
Checking, Cancelling or Correcting the
Timer Programming Information
E3TK0FD_EN.book Page 34 Monday, March 9, 2009 10:00 AM
34


Need help? Post your question in this forum.

Forumrules
1

Forum

toshiba-rdxv49

Reset search

  • Please what is the name of remote control for Toshiba videorecorder rdxv49dtkf? Many thanks for answer. John Submitted on 19-12-2021 at 21:38

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Toshiba RDXV49 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Toshiba RDXV49 in the language / languages: English as an attachment in your email.

The manual is 10,63 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info