Three-minute protection feature
A protection feature is provided that prevents the air conditioner from being activated for approximately 3 minutes when it is restarted
immediately after operation or when the power supply switch is set to on. This is used to protect the machine.
Heating characteristics (heat pump models)
Preheating operation
The air conditioner does not deliver warm air immediately after it is started.
Warm air flows out after approximately 5 minutes when the indoor heat exchanger has warmed up.
Warm air control
When the room temperature reaches the temperature setting, the fan indoor speed is automatically reduced.
The outdoor unit is stopped at this time.
Defrosting
If frost has formed on the outdoor unit during the heating operation, defrosting is started automatically (for approximately 5 to 10
minutes) to maintain the heating effect.
The fans in both the indoor and outdoor units stop during the defrost operation.
During the defrost operation, defrosted water is drained from the bottom plate of the outdoor unit.
Heating capacity
In the heating operation, heat is absorbed from outdoors and released into the room. That is called the heat pump system. When the
outdoor temperature is too low, usage of another heating apparatus in combination with the air conditioner is recommended.
Consideration for accumulated snow
Select the position for the outdoor unit where it will not be subjected to snow drifts, accumulation of leaves or other seasonal debris. It
is important that the air flow of the outdoor unit is not blocked as this will result in reduced heating or cooling performance. During the
heating mode and at sub-zero temperatures, the water drained off the outdoor unit as a result of the automatic defrost may
accumulate and freeze. It is important that adequate drainage or a soak-way be provided.
Power failure
Power failure during operation stops the unit completely.
The OPERATION indicator (green) on the indoor unit starts flashing when power is restored.
To restart operation, push the button on the remote control.
Lightning or a car wireless telephone operating nearby may cause the unit to malfunction. Turn the power supply switch off and then
on again. Push the button on the remote control to restart.
Air conditioner operating conditions
For proper performance, operate the air conditioner under the following temperature conditions.
If the air conditioner is used in conditions other than above, the safety protection functions may be activated.
When the indoor unit is connected to the inverter multi outdoor unit, you may feel a heating effect in heater mode even if it is set to
thermo off.
AIR CONDITIONER OPERATION AND PERFORMANCE
Cooling operation Outdoor temperature: 5°C to 43°C
Room temperature: 21°C to 32°C
CAUTION
Room relative humidity — less than 80%. If the air conditioner operates outside this
range, the surface of the air conditioner may attract condensation.
Heating operation
(heat pump models)
Outdoor temperature: –15°C to 24°C
Room temperature: Less than 28°C
Dry operation Outdoor temperature: 10°C to 43°C
Room temperature: 17°C to 32°C
29


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Toshiba RAS-B13GKVP at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Toshiba RAS-B13GKVP in the language / languages: English, German as an attachment in your email.

The manual is 2,79 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info