497518
3
Zoom out
Zoom in
Previous page
1/4
Next page
TEMPORARY OPERATION
12
In case of the misplaced or discharged remote control
Pressing the RESET button, the unit can start or stop
without using the remote control.
Operation mode is set on AUTOMATIC
operation, preset temperature is 24°C
and fan operation is automatic speed.
TIMER OPERATION
13
Everyday timer allows the user to set both the ON & OFF timers and will be activated on a daily basis.
Setting the ON Timer Setting the OFF Timer
1
Press
ON
: Set the desired ON timer.
Press
OFF
: Set the desired OFF timer.
2
Press
SET
: Set the timer. Press
SET
: Set the timer.
3
Press
CLR
: Cancel the timer. Press
CLR
: Cancel the timer.
Keep the remote control in accessible transmission to the indoor unit;
otherwise, the time lag of up to 15 minutes will occur.
The setting will be saved for the next same operation.
Note:
Setting Everyday Timer
1
Press
ON
: Set the ON timer.
3
Press
SET
.
2
Press
OFF
: Set the OFF timer.
4
Press
SET
button during the ( or )
mark ashing.
During the every day timer is activating, both arrows ( , ) are indicated.
PRESET OPERATION
14
Set your preferred operation for future use. The setting will be memorized by the
unit for future operation (except air ow direction).
1. Select your preferred operation.
2. Press and hold
PRESET
for 3 seconds to memorize the setting. The P mark
displays.
3. Press
PRESET
: Operate the preset operation.
AUTO RESTART OPERATION
15
To automatically restart the conditioner after the power failure (Power of the unit
must be on.)
Setting
1. Press and hold the RESET button on the indoor unit for 3 seconds to set the
operation. (3 beep sound and OPERATION lamp blink 5 time/sec for 5 seconds)
• Do not operate ON timer and OFF timer.
2. Press and hold the RESET button on the indoor unit for 3 seconds to cancel the
operation. (3 beep sound but OPERATION lamp does not blink)
To operate at super low fan speed for quiet operation (except in DRY mode)
Press
QUIET
: Start and stop the operation.
Note: Under certain conditions, QUIET operation may not provide adequate
cooling or heating due to low sound features.
To save energy while sleeping, automatically control air ow and automatically
turn OFF.
Press
COMFORT
SLEEP
: Select 1, 3, 5 or 9 hrs for OFF timer operation.
Note: The cooling operation, the set temperature will increase automatically
1 degree/hour for 2 hours (maximum 2 degrees increase). For heating
operation, the set temperature will decrease.
Cleaning the plasma air puri er unit (About 1000 hours performed)
(RAS-10, 13, 16SKVR-A Only)
1. Turn off air conditioner using remote control and power supply.
2. Take out the air inlet grille (See detail in installation manual).
3. Take out the plasma air puri er by grasp the handle, and the pull it out.
4. Soak in hot water at 40
o
C to 50
o
C for about 10 to 15 minutes and rub up,
down, left, right and rub surface gently with a sponge.
5. Allow to dry thoroughly in the shade.
6. Attach the plasma air puri er by grasp the
handle and insert into the right and left
guide rails.
7. Press both ends of the plasma air puri er
until the protrusions on both sides of the
plasma air puri er are completely inserted.
8. Attach the air lter, and then close the air
inlet grille.
QUIET OPERATION
16
COMFORT SLEEP OPERATION
17
SELF CLEANING OPERATION (COOL AND DRY OPERATION ONLY)
20
OPERATION AND PERFORMANCE
21
1. Three-minute protection feature: To prevent the unit from being activated for 3
minutes when suddenly restarted or switched to ON.
2. Preheating operation: Warm up the unit for 5 minutes before the heating
operation starts.
3. Warm air control: When the room temperature reaches the set temperature,
the fan speed is automatically reduced and the outdoor unit will stop.
4. Automatic defrosting: Fans will stop during defrost operation.
5. Heating capacity: Heat is absorbed from outdoors and released into the room.
When the outdoor temperature is too low, use another recommended heating
apparatus in combination with the air conditioner.
6. Consideration for accumulated snow: Select the position for outdoor unit
where it will not be subjected to snow drifts, accumulation of leaves or other
seasonal debris.
7. Some minor cracking sound may occur when unit operating. This is normal
because the cracking sound may be caused by expansion/contraction of
plastic.
Note: Item 2 to 6 for Heating model
Air conditioner operating conditions
Temp.
Operation
Outdoor Temperature
Room
Temperature
10, 13, 16SKVR-A
13, 16SKV-A
10SKV-A
Heating –15°C ~ 24°C –10°C ~ 24°C Less than 28°C
Cooling –10°C ~ 46°C 15°C ~ 43°C 21°C ~ 32°C
Dry –10°C ~ 46°C 15°C ~ 43°C 17°C ~ 32°C
The unit does not operate.
Cooling or Heating is abnormally low.
The power main switch is turned off.
The circuit breaker is activated to
cut off the power supply.
Stoppage of electric current
ON timer is set.
• The lters are blocked with dust.
The temperature has been set
improperly.
The windows or doors are opened.
The air inlet or outlet of the outdoor
unit is blocked.
The fan speed is too low.
The operation mode is FAN or DRY.
TROUBLESHOOTING (CHECK POINT)
22
REMOTE CONTROL A-B SELECTION
23
To separate using of remote control for each indoor unit in case of 2 air conditioner
are installed nearly.
Remote Control B Setup.
1. Press RESET button on the indoor unit to turn the air conditioner ON.
2. Point the remote control at the indoor unit.
3. Push and hold
CHK
button on the Remote Control by the tip of the pencil. “00” will
be shown on the display.
4. Press
MODE
during pushing
CHK
. “B” will show on the display and “00”
will disappear and the air conditioner will turn OFF. The Remote Control B is
memorized.
Note: 1. Repeat above step to reset Remote Control to be A.
2. Remote Control A has not “A” display.
3. Default setting of Remote Control from factory is A.
To start the sleep timer (OFF timer) operation
Press
SLEEP
: Select 1, 3, 5 or 9 hrs for OFF timer operation.
SLEEP TIMER OPERATION
18
Firstly, turn off the circuit breaker.
Filter Reset (Some models only)
FILTER lamp lights on; the lter must be cleaned.
To turn off the lamp, push the RESET button on the indoor unit or the FILTER
button on the remote control.
Indoor Unit and Remote Control
Clean the indoor unit and the remote control with a wet cloth when needed.
No benzine, thinner, polishing powder or chemically-treated duster.
Cleaning the air ionizer (Once every six months) (RAS-10, 13, 16SKVR-A Only)
1. Turn off air conditioner using remote control and power supply.
2. Fully open the vertical air ow louvers by hand.
3. Use a toothbrush to rub the ends of metal pin three or four times.
Note: Do not use cotton swabs or other objects with uff.
MAINTENANCE
19
To protect bad smell caused by the humidity in the indoor unit.
1. If the
button is pressed once during “Cool” or “Dry” mode, the fan will continue
to run for other 20 minutes, then it will turn off automatically. This will reduce the
moisture in the indoor unit.
2. To stop the unit immediately, press the
3 times within 30 seconds.
Note:
SELF CLEANING operation is default setting from factory.
To cancel this function, press and hold the reset button on the indoor unit for 20
seconds.
The SELF CLEANING operation will be cancelled. (5 beep sound but OPERATION
lamp does not blink)
• Do the same to set this function again. (5 beep sound and OPERATION lamp
blink 5 time/sec for 5 seconds)
AUTO RESTART operation will be cancelled by setting or cancellation of SELF
CLEANING operation. Set it again if necessary.
EN
1110250102-(1).indd 31110250102-(1).indd 3 1/4/07 4:48:08 PM1/4/07 4:48:08 PM
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Toshiba RAS-13SAV at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Toshiba RAS-13SAV in the language / languages: English as an attachment in your email.

The manual is 0,45 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info