497486
16
Zoom out
Zoom in
Previous page
1/59
Next page
16
7-2-1. Louver Control
(1) Vertical air flow louvers
Positions of vertical air flow louvers are automatically
controlled according to the operation status (COOL,
AUTO, DRY, FAN ONLY). Besides, positions of
vertical air flow louvers can be arbitrarily set by
pushing the [SET] button. The louver position which
has been set by the [SET] button is stored in
microcomputer, and the louver is automatically set at
the stored position in the next operation.
(2) Swing
If the [AUTO] button is pushed during running opera-
tion, vertical air flow louvers start swinging. When
the [AUTO] button is pushed again, swinging stops.
7-3. DRY Operation
(MODE of the remote control : DRY)
(1) Compressor, outdoor fan and operation display
are controlled as shown in Fig. 7-3-1.
(Room temp. Set temp.)
Set
temp.
ON
+3
+2
+1
0
OFF
OPERATION
display
Compressor
Outdoor fan
(RY01)
Common relay
(RY02)
ON:6min.
OFF:4min.
ON:5min.
OFF:5min.
ON
Fig. 7-3-1
The microprocessor turns the compressor on
and off at regular intervals (4 to 6 minutes on
and/or off).
During the compressor off, the indoor fan will
operate in the super low position.
The indoor fan will operate in the AUTO
position.
(2) The pattern of operation depending on the
relation between room temperature and set
temperature is shown below:
Room temp.
Set temp.+1
Set temp.
Compressor
Outdoor fan
Indoor fan
L. *S.L. S.L.L. L. S.L. L.
ON ON ON ON
OFF OFF OFF
*Super Low
Fig. 7-3-2
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Toshiba RAS-10YKX at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Toshiba RAS-10YKX in the language / languages: English as an attachment in your email.

The manual is 10,23 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info