(2) Self-diagnosis with remote control
With the indoor unit control, self-diagnosis of protective circuit action can be done by turning the remote
control operation into service mode, operating the remote control, observing the remote control indicators
and checking whether TIMER lamp blinks (5 Hz).
[ METHOD ]
Push the [CHK] button with a thin tip of pencil or
others. The remote control display shows .
Push key of TEMP. one by one.
The receiving beep Pi! is heard, and the timer
lamp of the air conditioner blinks.
(5 times for 1 sec.)
Operating key, the 35 check codes from
to are sent.
To reduce the check code number, push the
key of TEMP.
> <> <> <--
--> <> <---> <
If the check code agrees with the error code, the
receiving beep continues ringing Pi, Pi, Pi ...
(for approx.10 sec.), and all the LED of air
conditioner blink. (5 times for 1 sec.)
[ To release the servicing check ]
Push the [START/STOP] button.
Display screen returns to one before check.
The servicing check operation can be also
released by [ACL] button.
Hr.ON OFF TIMER
C
MODE FANTEMP.
TEMP.
START/STOP
TIMER
WC-E1BE
ECONO.
ON OFF RSV CNL
ACL CHK
FAN
SET
MODE
AUTO
AUTO
COOL
DRY
FAN ONLY
AUTO
LOW
MED.
HIGH
1
2
3
4
5
6
1
4
6
2
3
Block level Diagnosis function
Check
code
Block
Check
code
Symptom
Air
Co n ditio ne r
status
Condition
Judgment and action
Thermo. sensor
short/break.
Continued
operation
Indicated when
detected abnormal
1.Check thermo. sensor.
2.If it is OK, check P.C. board.
Heat exchanger
sensor
short/break.
Continued
operation
Indicated when
detected abnormal
1.Check heat exchanger
sensor.
2.If it is OK, check P.C. board.
Indoor fan lock,
abnormality of
indoor fan or
thermal fuse break.
All off
Indicated when
detected abnormal
Indoor
P.C. board
Abnormality of
other indoor unit
P.C. board.
All off Indicated when
detected abnormal
Replace P.C. board.
Contents detected by the check codes to are stored in memory of the microcomputer even if the power supply
is turned off. Therefore, contents of operations in the past are all displayed.
Table 9-2-3
35


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Toshiba RAS-10YA-HX RAS-07YKX-T at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Toshiba RAS-10YA-HX RAS-07YKX-T in the language / languages: English as an attachment in your email.

The manual is 10,23 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info