497456
3
Zoom out
Zoom in
Previous page
1/12
Next page
EN
ES
FR
INDOOR UNIT DISPLAY
1 Hi POWER (Green)
2 FILTER (Orange)
3 PRE. DEF (Preheat/Defrost)
(Orange)
4 TIMER (Yellow)
5 OPERATION (Green)
6 RESET button
2
1
Press
FIX
: Move the louver to the
desired vertical direction.
2
Press
SWING
: To continuously swing
the louver automatically and press
again to stop.
3
For horizontal direction, adjust
manually.
AIR FLOW DIRECTION
5
Note:
• Do not move the louver manually by others.
• The louver may automation positioning by some operation mode.
ONE-TOUCH
AUTOMATIC OPERATION
8
To automatically select cooling, heating, or fan only operation
1. Press
MODE
: Select A.
2. Press
TEMP
: Set the desired temperature.
7
Press the “ONE-TOUCH” button for fully automated operation that is
customized to the typical consumer preferences in your region of the world.
The customized settings control temperature air ow strength, air ow
direction and other settings to provide you alternate contact with “ONE-
TOUCH” of the button. If you prefer other settings you can select from the
many other operating functions of your unit.
Press
ONE-TOUCH
: Start the operation.
REMOTE CONTROL
6
PREPARATION BEFORE USE
3
Preparing Filters
1. Open the air inlet grille and remove the air lters.
2. Attach the lters. (see detail in the accessory sheet).
Loading Batteries
1. Remove the battery cover.
2. Insert 2 new batteries (AAA type)
following the (+) and (–) positions.
Clock Setup
1. Push CLOCK
by tip of the pencil.
If timer indication is ashing, go to the next step 2.
2. Press
ON
or
OFF
: adjust the time.
3. Press
SET
: Set the time.
Temperature Unit °F-°C Selection
1. Push and hold CHK button on the Remote
Control by the tip of the pencil, “00” will be
shown on the display.
2. Press
SLEEP
while pushing CHK .
Note: 1. Repeat above step to reset Remote
Control to be °F.
2. Operation mode and temperature
set will reset to initial setting after
change the temperature unit.
3. Default setting of Remote Control
from factory is °F.
AC
L
PRESET
ONE-TOUCH
QUIET
SWING
TIMER
ON
FILTER
CHK
˚C/˚F
CLOCK
OFF
CLR
SLEEP
SET
FIX Hi-POWER ECO
COMFORT
SLEEP
MODE
TEMP
FAN
1 Infrared signal emitter
2 Start/Stop button
3 Mode select button (MODE)
4 Temperature button (TEMP)
5 Fan speed button (FAN)
6 Swing louver button
(SWING)
7 Set louver button (FIX)
8 On timer button (ON)
9 Off timer button (OFF)
! Sleep timer button (SLEEP)
" Setup button (SET)
# Clear button (CLR)
$ Memory and Preset button
(PRESET)
% One-Touch button
(ONE-TOUCH)
& High power button
(Hi-POWER)
( Economy button (ECO)
) Quiet button (QUIET)
~ Comfort sleep button
(COMFORT SLEEP)
+ Filter reset button (FILTER)
, Clock Reset button (CLOCK)
- Check button (CHK)
REMOTE CONTROL A-B SELECTION
4
To separate using of remote control for each indoor unit in case of 2 air
conditioners are installed adjacent to each other.
Remote Control B Setup.
1. Press RESET button on the indoor unit to turn the air conditioner ON.
2. Point the remote control at the indoor unit.
3. Push and hold CHK
button on the Remote Control by the tip of the
pencil. “00” will be shown on the display.
4. Press
MODE
while pushing CHK . “B” will show on the display and “00”
will disappear and the air conditioner will turn OFF. The Remote Control
B is memorized.
Note: 1. Repeat above step to reset Remote Control back to A.
2. Remote Control A have not “A” display.
3. Default setting of Remote Control from
factory is A.
SYSTEM CHARACTERISTICS
1
1. Three-minute time delay: To protect against frequent compressor starts.
2. Preheating operation: Warm up the unit for several minutes before
blowing warm air.
3. Warm air control: When the room temperature reaches the set
temperature, the fan speed is automatically reduced and the outdoor unit
will stop.
4. Automatic defrosting: Fans will stop during defrost operation.
5. Heating capacity: Heat is absorbed from outdoor and released into
the room. When the outdoor temperature is too low, use another
recommended heating apparatus in combination with the air conditioner.
6. Some minor cracking sound may occur when unit operating. This is
normal and is caused by expansion/contraction of plastic.
Note: Item 2 to 5 for Heating model
Air conditioner operating conditions
Temp.
Operation
Outdoor Temperature
Room
Temperature
Heating 5°F ~ 75°F (–15°C ~ 24°C) Less than 82°F (28°C)
Cooling 14°F ~ 115°F (–10°C ~ 46°C) 70°F ~ 90°F (21°C ~ 32°C)
Dry 14°F ~ 115°F (–10°C ~ 46°C) 62°F ~ 90°F (17°C ~ 32°C)
CLR
SLEEP
SET
“B” Display
“00” Display
1110650133-1-EN.indd 31110650133-1-EN.indd 3 1/4/10 3:50:57 PM1/4/10 3:50:57 PM
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Toshiba RAS-09LKV-UL at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Toshiba RAS-09LKV-UL in the language / languages: English, French, Spanish as an attachment in your email.

The manual is 3,66 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info