9-3-4. Only Compressor does not Operate
Shut off the power supply
from AC outlet once and
turn it on after 5 seconds.
Does the OPERATION lamp blink?
Does the power turn on by
pushing the [START/STOP] button
of the remote control?
Is cable connection between indoor
and outdoor units correct?
Replace the
P.C. board.
See Power can not be turned on.
NO
NO
NO
NO
YES
YES
YES
YES
Is the voltage across the outdoor terminal
( 1 - 2 ) AC 220240V (AC 220V)
**
?
YES
Are all the cords for compressor normal?
Is the compressor motor winding normal?
(Check the winding resistor.)
Is the capacitor for compressor normal?
Is the overload relay normal?
Does the compressor start?
Compressor starts but
it stops after a while?
Cables between indoor and
outdoor units are defective.
Re-wire or replace the defective cords.
Compressor is defective.
Capacitor is defective.
Overload relay is defective.
Compressor is defective.
Correct cabling between indoor
and outdoor units.
NO
NO
NO
NO
NO
NO
YES
YES
YES
YES
YES
YES
See Power can not be turned on.
YES
Is the gas quantity normal?
(Check the pressure)
Gas shortage (Gas leakage)
NO
Compressor is defective
Is the voltage across the indoor terminal
( 1 - 2 ) AC 220240V (AC 220V)
**
?
Relays (RY01, RY02)
or IC31 or IC30 is failure.
**
for model RAS-07YKX-T, RAS-10YKX-T
38


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Toshiba RAS-07YK-E at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Toshiba RAS-07YK-E in the language / languages: English as an attachment in your email.

The manual is 10,23 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info