TOSHIBA RAS-07/10/13UKP (US) 1075000802
TEMPORARY button
TEMPORARY button
This air conditioner is equipped with an Automatic restarting facility which allows the air conditioner to resume
the set operating conditions in the event of a supply power shutdown without the use of the remote control.
The operation will resume without warning three minutes after the power is restored.
To set the auto restart function, proceed as follows:
The power supply to the unit must be on the function will not set if the power is off.
To enable the auto restart function, push the TEMPORARY button continually for 3 seconds.
The air conditioner will acknowledge the setting and beep 3 times. The system will now restart automatically.
The above auto restart settings can be carried out:
(1) When the air conditioner is in stand-by (not running).
Push the TEMPORARY button for more than 3 seconds.
The air conditioner starts to operate.
The green lamp will be indicated.
About 3 seconds after, the air conditioner beeps 3 times.
The lamp will change from green to orange.
The air conditioner is operating.
If the air conditioner is not required to run at this time, push the
TEMPORARY button once more or use the remote control to stop the
air conditioner.
(2) When the air conditioner is in operation.
Push the TEMPORARY button for more than 3 seconds.
The air conditioner stops operating.
The green lamp goes off.
The air conditioner beeps 3 times 3 seconds later, after pushing the button.
The air conditioner stops.
If the air conditioner is not required to stop at this time, use the remote control to restart the air conditioner.
During the subsequent operation, the orange lamp is indicated.
The auto restart operation will not accept an instruction if timer operation with the remote control is selected.
The louver swing (AUTO) operation will not resume, after restarting the air conditioner by the AUTO
RESTART OPERATION.
To cancel the auto restart operation, proceed as follows:
Repeat the setting procedure: the air conditioner will acknowledge the instruction and beep three times.
The air conditioner will now require to be manually restarted with the remote control after the main supply is
turned off.
Cancellation is carried out:
(1) When the air conditioner is in stand-by (not running).
Push the TEMPORARY button for more than 3 seconds.
The air conditioner starts to operate.
The orange lamp will be indicated.
About 3 seconds after, the air conditioner beeps 3 times.
The lamp will change from orange to green.
The air conditioner is operating.
If the air conditioner is not required to run at this time, push the
TEMPORARY button once more or use remote control to stop the air
conditioner.
(2) When the air conditioner is in operation.
Push the TEMPORARY button for more than 3 seconds.
The air conditioner stops operating.
The orange lamp is turned off.
About 3 seconds after, the air conditioner beeps 3 times.
The air conditioner stops.
If the air conditioner is not required to stop at this time, use the remote control to restart the air conditioner.
During subsequent operation, the green lamp is indicated.
AUTO RESTART OPERATION
HOW TO SET THE AUTO RESTART
HOW TO CANCEL THE AUTO RESTART
The AUTO RESTART OPERATION is not set to work on shipment from the factory, and so it is necessary
to set it to function as required.
INFORMATION
TEMPORARY button
TEMPORARY button
01RAS-07/10/13UKP P13-19 2/1/02, 12:04 AM14
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Toshiba RAS-07UKP-E at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Toshiba RAS-07UKP-E in the language / languages: English as an attachment in your email.

The manual is 3,49 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info