475352
45
Zoom out
Zoom in
Previous page
1/110
Next page
45
CONTROLS AND FEATURES
English
NOTE: The adjustments made for Red / Green / Blue are
stored separately for each IRE setting. (There are ten IRE
settings from 10 to 100.)
Colour Calibration
The aim of Colour Calibration is to measure and/or adjust the
colour response (White Balance) of your LCD panel.
Colour Calibration is used by various fields, such as gaming,
photography, engineering, medical and more. In order to
calibrate a display correctly, you need a colour analyzer TPA-1
(not supplied).
NOTE: This feature is available when the Picture Mode option
is Hollywood Pro.
Apply Calibration
a In the Expert Picture Settings menu, press B or b to
select Colour Calibration and press OK.
b Press B or b to select Apply Calibration and press C
or
c to select Enabled.
Manual Colour Calibration
a In the Colour Calibration menu, press B or b to
select Manual Colour Calibration and press OK.
b Place the probe of the colour analyzer over the square
on screen to measure.
c Input the value measured with the colour analyzer
using the number buttons (0-9).
d Press BbC c and input the values to fill all RGBxy
matrix table.
e Highlight Start and press OK.
Please wait until you see “Manual Colour Calibration
has been completed.” on screen.
To return to factory setting
a Highlight Reset and press OK.
Auto Colour Calibration
a In the Colour Calibration menu, press B or b to
select Auto Colour Calibration and press OK.
b Connect the USB colour analyzer to the USB 1 or USB
2 port.
c Place the probe of the USB colour analyzer over the
square on screen and press OK.
Auto Colour Calibration will start.
Please wait until you see “Auto Colour Calibration has
been completed.”.
Gamma Calibration
a In the Expert Picture Settings menu, press B or b to
select Gamma Calibration and press OK.
b Press B or b to select Apply Calibration and press C
or
c to select Enabled.
c Press B or b to select Auto Gamma Calibration and
press OK.
d Connect the USB colour analyzer to the USB 1 or USB
2 port.
e Input the target value and place the USB colour
analyzer over the square on screen.
f Highlight Start and press OK.
Auto Gamma Calibration will start.
Please wait until you see “Auto Gamma Calibration
has been completed.” on screen.
To return to factory setting
a Highlight Reset and press OK.
Resetting to the factory defaults
a In the Expert Picture Settings menu, press B or b to
select Reset and press OK.
A confirmation screen appears.
b Select Yes and press OK.
Manual Colour Calibration
Red
0.642
x
y
0.277
0.143
0.335
0.603
0.067
Blue
Green
Start
Reset
Please input the value measured with the coulour analyser.
Red
0.642
x
y
0.277
0.143
0.335
0.603
0.067
Blue
Green
Auto Gamma Calibration
Target Colour Temperature
0.313
x
y
2.4
0.329
Target Gamma
Start
Reset
Please input the target value and place the USB colour analyser
over the square.
45


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Toshiba 55WL863G at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Toshiba 55WL863G in the language / languages: English as an attachment in your email.

The manual is 12,69 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Toshiba 55WL863G

Toshiba 55WL863G User Manual - German - 110 pages

Toshiba 55WL863G User Manual - Dutch - 110 pages

Toshiba 55WL863G User Manual - French - 110 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info