636410
38
Zoom out
Zoom in
Previous page
1/60
Next page
36
Check and Adjusting
Horizontal Calibration
(1) Checking Calibration
1 Steadily set up a tripod approximately 50m from a
staff member or wall and adjust so that the head
of the tripod is horizontal.
Mount the instrument on the tripod in the direction
shown in the right figure (Y-axis facing the wall).
2 While pressing the [Y] key, turn on the power
switch.
3 The flashing axis is the selected one.
Select the axis to check using the arrow keys
(right and left) and press the [ENT] key to lock.
ESC
MENU
ENT
Y
Y
-
Y+
X+
X
-
50m (164feet)
Turn on the power while pressing the [Y] key.
Select the axis using the arrow keys (right and left)
and press the [ENT] key.
XY
WX
Level sensor
Staff or Wall
38


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Topcon RL200 1S at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Topcon RL200 1S in the language / languages: English as an attachment in your email.

The manual is 4,42 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info