BD-4601 (BPM Arm 1500)
14 Technische Daten
Modell
Energieversorgung
Messbereich
Genauigkeit
Drucksensor
Aufpumpen
Ablassen
Speicherkapazität
Selbstabschaltung
Betriebsumgebung
Lager/transport
umgebung
Gewicht
Umfang Manschette-Arm
Altersbeschränkung
Patient
Klassifizierung
BD-4601 (BPM Arm 1500)
4 x AAA (1,5 V)-Alkalibatterien
Blutdruck: 0~300 mmHg
Puls: 40~199 Schläge/Minute
Blutdruck: ± 3 mmHg
Puls: innerhalb ± 5 % des abgelesenen Messwerts
Halbleiter
Automatisch – mit Pumpe angetrieben
Automatisches Druckfreigabe-Ventil
3 Speicherzonen mit jeweils 40 Speicherplätzen
1 Minute nach der letzten Tastenbedienung
Temperature 5°C ~ 40°C (41°F ~ 104°F).
Humidity 15% ~ 93% R.H.
Temperature -25°C ~ 70°C (-13°F ~ 158°F)
Humidity 93% R.H.
212 g (mit Batterien)
23~33 cm (9~13 Zoll)
Über 18 Jahre
Intern angetriebenes Gerät
Klassifikation des Typs BF(Anwendungsteil)
IPX0
Nicht geeignet für den Betrieb in Gegenwart von entflammbaren
Anästhetika-Mischungen mit Luft, Sauerstoff oder Stickoxid
Ununterbrochener Betrieb mit Kurzzeitladung
15 Wartung
Reinigen Sie das Gerät mit einem leicht angefeuchteten Tuch bzw. milden Reinigungsmittel und
wischen Sie es sofort mit einem trockenen Tuch ab.
Verwenden Sie zum Reinigen des Geräts keine starken Reinigungsmittel oder Chemikalien.
Die Manschette nur mit einem trockenen Tuch abwischen.
Gibt die Anzahl der gespeicherten
Messungen an.
Wird angezeigt, wenn ein Messfehler
vorliegt oder der angezeigte Blutdruckwert
extrem niedrig oder hoch ist.
Alle Akkus/Batterien durch neue
ersetzen.
Dabei auf die richtige Polarität
(+ und -) achten.
Luftkreislauf-Fehler.
Manschettenschlauch ist evtl. nicht richtig
angeschlossen.
Anschluss prüfen.
Messung erneut durchführen.
Aufpumpdruck über 300 mmHg Gerät ausschalten, dann erneut
messen.
Fehler beim Ermitteln der Messdaten Messung erneut durchführen.
44


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Topcom BD-4601 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Topcom BD-4601 in the language / languages: English, German, Dutch, French, Swedish, Spanish as an attachment in your email.

The manual is 21,24 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info