BD-4601 (BPM Arm 1500)
14 Technische specificaties
Model
Voeding
Meetzone
Nauwkeurigheid
Druksensor
Oppompen
Leeglopen
Geheugencapaciteit
Automatische
uitschakeling
Bedrijfstemperatuur
Opslag / transport
temperatuur
Gewicht
Omtrek armmanchet
Leeftijdsbeperkingen
Classificatie
BD-4601 (BPM Arm 1500)
4 alkalinebatterijen (AAA – 1,5 V)
Druk: 0~300 mmHg
Polsslag: 40~199 slagen/minuut
Druk: ± 3 mmHg
Polsslag: binnen ± 5% van meetresultaat
Halfgeleider
Automatisch – pompgestuurd
Automatische drukaflaatklep
3 geheugenzones met elk 40 geheugenplaatsen
1 minuut nadat voor het laatst een knop ingedrukt is
5°C ~ 40°C (41°F ~ 104°F) Humidity 15% ~ 93% R.H..
-25°C ~ 70°C (-13°F ~ 158°F) Humidity 93% R.H.
212 g (met batterijen)
23~33 cm (9~13 inch)
Ouder dan 18 jaar
Toestel met interne voeding
Classificatie type BF (toegepast onderdeel)
IPX0
Niet geschikt voor gebruik in de buurt van brandbare anesthetische
mengsels met lucht of met zuurstof of lachgas.
Continu bedrijf met korte belastingscyclus
15 Onderhoud
Gebruik een met water of een mild reinigingsmiddel bevochtigde doek om het toestel af te vegen
en droog het onmiddellijk met een droge doek.
Gebruik geen detergent of sterke chemicaliën om het toestel te reinigen.
Gebruik enkel een droge doek om de manchet af te vegen.
Haal de batterijen uit het toestel als het gedurende lange tijd niet zal worden gebruikt
(lekkage van batterijzuur kan storingen veroorzaken).
Geeft het aantal metingen weer dat is
opgeslagen in het geheugen.
Verschijnt wanneer er een meetfout is
opgetreden of wanneer de gemeten
bloeddrukwaarde extreem hoog of laag is.
Vervang alle batterijen door nieuwe.
Zorg ervoor dat de +/- polen correct
zijn.
Fout in het luchtcircuit.
De luchtslang van de manchet is mogelijk
niet correct aangesloten.
Controleer de aansluiting van de
manchet.
Meet opnieuw.
De vuldruk is meer dan 300 mmHg. Schakel het toestel uit en meet
opnieuw.
Fout bij bepaling van de meetgegevens. Meet opnieuw.
22


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Topcom BD-4601 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Topcom BD-4601 in the language / languages: English, German, Dutch, French, Swedish, Spanish as an attachment in your email.

The manual is 21,24 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info