622631
5
Zoom out
Zoom in
Previous page
1/22
Next page
FT5130
V. 01 07/07/2015 5 ©Velleman nv
5.4 Changing a Gas Cylinder
Only replace the gas cylinder in a non-flammable and non-smoking environment.
1. Close the valve of the gas cylinder.
2. Unscrew the regulator from the valve of the cylinder. Remove the device. Take the empty cylinder away
from the heater.
3. Make sure the sealing of the pressure controller is still place.
4. Install the heater onto a new gas cylinder. To do so, follow the instructions described above.
5.5 Storage
1. Disconnect the heater from the cylinder. Refer to the instructions described above.
2. Store the cylinder in a well-ventilated area, preferably in an outhouse, away from any combustible
materials.
3. Store the heater in its original package and keep in a dry and dust-free environment.
6. Cleaning and Maintenance
Have the heater checked by a qualified authorized technician once a year.
Periodically check that the gas hose is intact. If it is expired, have it replaced. Only use a gas hose of the
correct length.
Cleaning
Clean the heater using a soft and dry cloth. Avoid using aggressive, abrasive or inflammable products.
7. Technical Specifications
heating power
2.6-4.5 kW
type of gas
butane/propane (i3+)
maximum pressure
butane
28-30 Mbar
propane
37 Mbar
consumption
330 g/h
pressure valve
required, not included
Use this device with original accessories only. Velleman nv cannot be held responsible in the event
of damage or injury resulting from (incorrect) use of this device. For more info concerning this
product and the latest version of this manual, please visit our website www.toolland.eu. The
information in this manual is subject to change without prior notice.
© COPYRIGHT NOTICE
The copyright to this manual is owned by Velleman nv. All worldwide rights reserved. No part of this
manual may be copied, reproduced, translated or reduced to any electronic medium or otherwise without the
prior written consent of the copyright holder.
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Toolland FT5130 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Toolland FT5130 in the language / languages: English, German, Dutch, French, Portuguese, Spanish as an attachment in your email.

The manual is 0,43 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info