Cleaning and care
Only service and clean the appliance if it is switched off and the mains
power plug has been disconnected from the mains power supply.
After wash-vacuuming
Please use a moist soft cloth to clean the appliance housing.
Do not use any aggressive cleaning agents or solvents.
Remove fresh water tank and empty.
Empty waste water tank.
Clean anti-splash grid, waste water tank and wet filter using
clear, possibly warm water.
Check motor protection filter for contamination and wash
under flowing water and renew, if necessary.
Keep float (13b) in the waste water tank clean and fully
functional at all times. This float interrupts the suction operation
if the waste water tank is full.
Dry up spray water in suction chamber with soft cloth.
Remove contamination from the appliance intake and from the
inside of the housing cover.
The housing cover can be taken off the appliance
for easier cleaning.
To do this open the cover and swing vertically. Press the cover
forwards until it slides out of the hinge. Afterwards swing the
cover upwards and out of the way.
Insert in the housing cover vertically and close it to fasten. The
cover automatically clicks into the hinge.
To service the pump and valves fill the fresh
water tank with clear water, and put the spraying
system into operation (activate the lever on the
shut-off valve) over a wash basin, for example.
The appliance and accessory parts are to be thoroughly dried
after being used for cleaning.
Activate the shut-off valve lever to make the system completely
free from any remaining pressure.
After vacuuming
1. AQUA filter system
Open housing cover by lifting up the cover catch.
Remove waste water tank.
Pull the AQUA filter (12) out of the waste water tank by its grip and
pour the waste water away (for example into the toilet).
Remove foam filter (12a). To do this pull the AQUA filter frame slightly
upwards and then fold it over to the side out of the way.
Now thoroughly rinse the AQUA filter, foam filter, wet
filter and the waste water tank with clear water. Do not
use any cleaning agents.
It is essential to ensure that the parts are dry before
using again.
The filter can be also removed for easier cleaning if dirt and fluff have
blocked the suction filter (12b); refit the suction filter after cleaning.
Remove contamination and fluff from the
appliance intake.
2. HEPA filter
Your TWIN T2 PARQUET is equipped with a high quality HEPA filter
(14), which can be cleaned several times depending on your needs
and the type of dust found in your home.
Clean your appliance if needed (at the latest every six months) and if
the suction power decreases.
Remove the HEPA filter from the appliance and knock out the
dirt on a firm surface.
If the filter is strongly contaminated it can also be rinsed out
with clear water (without cleaning agent) and be subsequently
cleaned by knocking out the dirt.
Do not use any brushes for cleaning. Always
allow the filter to dry thoroughly before fitting it
back into the appliance again.
Do not damage the filter fins when cleaning the HEPA
filter.
The filter has to be replaced by a new filter should the suction power
of the appliance not improve to a considerable extent after cleaning
the HEPA filter.
3. MKA microfilter
The MKA microfilter (19) has to be replaced every six months.
To do this press down the two plastic lugs on the blow-out cover and
fold it back.
Replace the MKA microfilter. Close the blow-out cover again.
After Sales Service supplies /
special accessories
An extensive range of special accessories and After Sales Service
supplies are available for your THOMAS TWIN T2 PARQUET.
Get further details by returning the accompanying reply card to us or
get further information from your specialist dealer or directly from the
THOMAS Customer Service Department.
Note!
You can only assure a properly functioning appliance and efficient
cleaning by using original THOMAS accessories.
Customer service
Ask your dealer for the THOMAS Customer Service
Area Centre responsible for you.
At the same time please tell your dealer the details
given on the rating plate of the THOMAS TWIN T2
PARQUET:
Repairs more especially to electrical parts must be
carried out only by a qualified electrician. This, in turn,
ensures that your appliance remains fully functional
and safe in operation.
As a consequence, in case of irregularities you should
get in touch with your specialist dealer or contact the
THOMAS Customer Service Department directly.
Tel. <0049>(0)2735/788-581 or 582
Fax: <0049>(0)2735/788-599
23


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Thomas Twin T2 Parquet Aquafilter at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Thomas Twin T2 Parquet Aquafilter in the language / languages: English, German, French, Polish, Turkish as an attachment in your email.

The manual is 10,65 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Thomas Twin T2 Parquet Aquafilter

Thomas Twin T2 Parquet Aquafilter User Manual - German - 10 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info