When filling make sure that no impurities get
into the fresh water tank, in order to avoid a
malfunction of the shut-off valve.
Fill up with cleaning concentrate and water up to the grip lug
(max. 2.4 litres).
We recommend THOMAS ProTex original cleaning
concentrate for cleaning carpets.
See label on the cleaning concentrate bottle for application
and dosage.
Use hand warm water (max. 30°C).
Connect suction hose and fit telescopic suction tube.
Fit carpet spray nozzle and spray hose with fast coupling to the
suction tube by leading the hose upwards up to the shut-off
valve and lock by turning. Afterwards, fasten the spray hose
along the suction tube by means of the two clips.
Pull out the mains power supply plug and cable from the
appliance and connect.
Switch on the appliance and set it for maximum suction power.
Switch on pump. Control lamp comes on.
Press the lever on the shut-off valve (24) until cleaning liquid
escapes. Draw the nozzle straight across the carpet and press
it down at the same time. The spraying volume can be set as
required by means of the little hand wheel on the handle.
Release the lever to stop spraying at the end of one run
or when stopping work. When the sprayed liquid has been
sucked up, lift the nozzle and begin a new run but overlap
slightly. In this way you can clean the entire area section by
section.
Should there still be traces of liquid remaining on the cleaned
areas, this liquid can be sucked up without spraying again.
Make sure that the mechanical suction regulation (25) is
completely closed.
In case of very tough dirt you can apply cleaning liquid
while moving the carpet spraying nozzle forwards. The same
treatment can also be applied by working in the ‘pump only’
position, i.e. sucking up function shut off.
Ensure that you do not spread too much liquid, since this may cause
waves or bumps in the carpet. These will disappear only after being
allowed to dry for a longer period of time.
Wash-vacuuming
Information for use
Caution! Petrol, thinners, heating oil, etc., can develop explosive
vapours and mixtures if mixed with the intake air.
Acetone, acids and solvents can attack the materials used in the
production of the appliance. Both clean and waste water can be
sucked up without any hesitation.
After sucking up liquids always clean and dry the waste water tank
and all the parts used.
Never suck up liquids without the waste water tank
and the installed anti-splash grid.
Your THOMAS TWIN T2 PARQUET is not suitable for sucking up
larger quantities of liquid from containers or basins.
Caution! Never activate the pump without water in the fresh
water tank.
Always empty and clean the appliance every time it has been
used for wash-vacuuming. Waste water and moist parts favour
the growth of bacteria and fungi (see cleaning and maintenance
instructions).
Only use THOMAS original products and parts to ensure
perfect cleaning results.
You can get further supplies of the cleaning concentrate
from your specialist dealer or the THOMAS Works Customer Service
Department.
Before cleaning carpets
Make sure that everything you want to wet clean is also suitable for
wet cleaning. Do not wet clean your sensitive, hand-woven or non-
fast dyed carpets, for example.
To check this, put a small quantity of THOMAS cleaning concentrate on
a white cloth and rub on the carpet at a not too obvious spot. It can
be assumed that the dye is colourfast should no traces of dye appear
on the cloth.
Should this not be the case, do not wet clean the carpet.
Please consult your specialist carpet dealer should you have any doubts.
Was the carpet shampooed before, it may well be that increased
foaming will occur in the waste water tank while using the THOMAS
TWIN T2 PARQUET for the first time. Pour half a cup of vinegar into
the waste water tank to prevent further foaming.
Immediately switch off the appliance and empty the waste water tank
should foam escape from the air outlet.
After a thorough cleaning with THOMAS cleaning concentrate,
further increased foaming will not occur, because THOMAS cleaning
concentrate contains a special foam-stop.
You should not step on your cleaned carpet as long as it is wet or moist.
The room should be well ventilated both while cleaning and after-
wards, to ensure quickly drying.
Carpet cleaning
Put the 2-piece anti-splash grid together.
Remove the AQUA filter from the waste water tank by its grip
and fit the anti-splash grid.
Remove HEPA filter from the appliance.
Fit the anti-splash grid and waste water tank in the appliance.
Make sure that both the wet filter (13a) and the motor
protection filter (15) are fitted.
Remove the fresh water tank for filling (pull out vetically), or you
can fill it while still in place; in that case, simply remove the lid of
the fresh water tank.
Absaugen und
Aufrichten
Arbeitsrichtung
Einsprühen
Saugrohr
Druckleitung
Lösen und Auswaschen
Suction tube
Releasing and washing out
Spraying
Sucking up and
straightening
Spray hose
Working direction
Spray extraction system
Spray the cleaning liquid deep into the carpet under pressure
This releases the dirt and washes out deep down into the fibres
Suck up the waste water at full power and straighten up the
carpet pile again.
This should be always carried out in a single operation.
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Thomas Twin T2 Parquet Aquafilter at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Thomas Twin T2 Parquet Aquafilter in the language / languages: English, German, French, Polish, Turkish as an attachment in your email.

The manual is 10,65 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Thomas Twin T2 Parquet Aquafilter

Thomas Twin T2 Parquet Aquafilter User Manual - German - 10 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info