In your own interest of safety, it is law that all gas appliances be installed by an approved
competent person who will undertake to work to safe and satisfactory standards. Failure to
install the appliance correctly could invalidate any warranty or liability claims and lead to
prosecution. This appliance shall be installed in accordance with the local and
national/European standards in force. Particular attention shall be given to the requirements
regarding ventilation. Read the instructions before installing or using this appliance.
VENTILATION
This appliance is suitable for installation into Holiday Homes, Touring Caravans and Boats. In all
cases the national standards with regard to ventilation for the particular vehicle into which the
appliance is to be installed must be adhered to.
The appliance MUST have a gas escape hole (min size 50mm Ø; max 70mm Ø; or shaped hole
of equivalent area – 1965 to 3850mm
2
) in the floor, directly beneath the appliance. The hole
MUST vent to the outside.
LOCATION OF APPLIANCE
This appliance maybe installed in a kitchen/kitchen diner but NOT in a room containing a bath or
a shower. LP gas appliances must not be fitted below ground level. e.g. in a basement.
POSITION
The performance of the appliance meets the requirements of the European Standard for
Domestic Cooking Appliances (EN30) which specifies a maximum allowable temperature rise of
the furniture into which the appliance is installed of 65
o
C above the ambient temperature. To
ensure compliance with the standard it is important the installation follows the dimensions as
shown in this manual.
A cutout should be prepared – see Figs. 3,4 & 5 for model and details. The location of the cutout
MUST comply with Fig. 2 after the hob is installed – ie a direct distance of 200mm must exist
between the edge of the burner and combustible material unless protected by a layer of non-
combustible material.
The appliance should be fixed in place using the supplied clamps – see Figs. 6, 7 & 8 for model
type and clamping method.
For models with a glass lid, the distance from the edge of the burner to the rear wall can be
reduced to 110mm.
All combustible materials such as curtains and shelves must be kept well clear of the appliance.
Any fitments such as a cupboard above the appliance must have a minimum clearance of
500mm between the fitment and the top of the pan support.
This appliance must be positioned free from draughts, which may affect the combustion, and in
a manner that will prevent the accumulation of unburnt gas. When in use ensure that air vents
are not inadvertently blocked or shut off.
We recommend the underside of the hob be shielded particularly if this area is to be used for
storage or the installation of another appliance. The shield should be fabricated from
non-combustible material, but if the enclosure is manufactured from combustible material there
should be a minimum distance of 120mm between the worktop (top face) and the shield.
THIS AIR SPACE MUST BE WELL VENTILATED
INSTALLATION
GB
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Thetford SERIE 960 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Thetford SERIE 960 in the language / languages: English as an attachment in your email.

The manual is 0,72 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Thetford SERIE 960

Thetford SERIE 960 User Manual - German - 17 pages

Thetford SERIE 960 User Manual - Dutch - 17 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info