9
+10Run some water into the bowl by moving the flush
handle up and down once more or open the valve
b
lade under the toilet bowl by pulling it towards you.
Y
our Thetford toilet is now ready for use.
S/CS AND CWE
9
a+10Run some water into the bowl by pressing the flush
button once or open the valve blade under the toilet
bowl by pulling it towards you.
Y
our Thetford toilet is now ready for use.
S/CS
Note! Some vehicles are equipped with a high-pressure
water pump. This can result in a powerful flush that spills
over the top of the toilet bowl. In this case use the
pressure reducer supplied (packed with the toilet
instructions). This pressure reducer must be inserted into
the water hose at the point where the toilet is connected to
the central water system.
CW
11 After use, open the valve blade (if it is still closed) and
flush the toilet by moving the flush handle up and
down. TIP! The flush of your toilet will be more
effective if you pulsate the flush by pressing the flush
button several times in a row. Close the valve blade
after flushing.
S/CS AND CWE
11aAfter use, open the valve blade (if it is still closed) and
flush the toilet by pressing the flush button. TIP! The
flush of your toilet will be more effective if you pulsate
the flush by pressing the flush button several times in
a row. Close the valve blade after flushing.
Note! Do not leave water in the bowl if the toilet is not
being used. This does not help to reduce unpleasant
smells and only leads to flooding.
Important Warning Notice! Please do not travel with a
flush water tank that is too full (we advise empty, but
for sure not filled more than half-full). Do not travel
with water in the toilet bowl. Failure to adhere to this
notice may result in water damage to your caravan or
motor home. Please avoid to travel with a waste-
holding tank that is more than 3/4 full. This may cause
leakage through the venting system.
EMPTYING
The waste holding tank must be emptied, at the latest,
when the warning lamp is lit. It is advisable to empty the
waste holding tank earlier. The warning lamp illuminates
when the waste holding tank contains in excess of 15 litres.
This indicates that a capacity of 2 litres is left, which will
allow approximately 5 uses.
Note! Do not allow the waste holding tank to become too
full.
GB
- 2-
1
2 Make sure that the valve blade is closed. Open the
a
ccess door outside the vehicle. Pull the safety catch
upwards and remove the waste holding tank.
1
3 Carry the tank by the handles to a normal toilet or to a
legal waste disposal site. Place the waste holding tank
u
pright on the ground and turn the emptying spout
upwards.
1
4 Remove the emptying spout cap. Hold the waste
holding tank by the upper handle nearest to the
emptying spout. Hold the rear handle with your other
h
and so that you can operate the vent plunger with
your thumb. Keep the vent plunger pressed in to
e
nsure the tank is emptied without splashing.
Note! The vent plunger should only be pressed once
the emptying spout is pointing downwards!
After emptying, flush the tank and clean the valve blade
thoroughly with water. Also, clean the valve blade with
water. Slide the waste holding tank into the toilet and
close the access door.
STORAGE
S / CS
First empty the central water system. Press the flush button
until the remaining water has been pumped away. Empty
the waste holding tank. To allow the tank to dry, do not
place the cap back on the emptying spout of the waste
holding tank.
CW / CWE
Empty the flush water tank by moving the flush handle up
and down (C-200 CW) or by pressing the flush button
(C-200 CWE). Flush the tank until it is empty and no more
water is being pumped out. Then empty the waste holding
tank. To allow the tank to dry, do not place the cap back on
the emptying spout of the waste holding tank. Place a
sufficiently large bowl under the drain plug to catch the
remaining water from the water tank and remove the drain
plug.
CLEANING AND MAINTENANCE
The waste holding tank seal, the automatic pressure
release vent seal and the cap seal must be cleaned
regularly. When the toilet is being used frequently, monthly
cleaning is generally sufficient. We advise cleaning the
seals and valve blade with Thetford Bathroom Cleaner.
Note! Never use household cleaners (bleach, solvents or
other powerful cleaning agents). These may cause
permanent damage to the seals and other toilet components.
If the toilet will not be used for a long period, it is
advisable to clean the seals and coat them lightly with
Thetford Seal Lubricant. This will ensure that they remain
in good condition (supple).
Note! Never use Vaseline or any vegetable oil. These may
cause leakage.
N.B. The valve blade seal is a part of the toilet that is
29744-1212-V01 Binnenwerk_29744 binnenwerk 27-08-13 12:16 Pagina 2
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Thetford C200 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Thetford C200 in the language / languages: English, German, Dutch, Danish, French, Italian, Portuguese, Swedish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 2,94 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Thetford C200

Thetford C200 Installation Guide - English - 21 pages

Thetford C200 Installation Guide - German - 21 pages

Thetford C200 User Manual - German - 12 pages

Thetford C200 User Manual - Dutch - 12 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info