Manuale d'installazione, uso e manutenzione
SOFIA ILARIA VITTORIA ANNA
B Smoke by-pass
This device creates a direct bypass for the flue gases which facilitates both the lighting and refuelling operations. The riddling tool
provided must be used when activating it and only when lighting or stoking the fire.
IT IS PROHIBITED TO LEAVE THE SMOKE BY-PASS OPEN DURING NORMAL OPERATION.
Leaving the Smoke by-pass open during normal operation results in higher fuel consumption than the declared
quantity, a considerable drop in efficiency and exposure of the appliance to extremely high temperatures. For this
reason the warranty does not cover any direct or indirect damages caused by prolonged exposure of the appliance to
these temperatures. ATTENTION: The temperature of the Smoke by-pass is very hot while the appliance is
operating, so take care not to touch it. The riddling tool provided must be used when handling it.
Pulling the lever outwards activates the smoke bypass, whereas pushing it inwards activates the normal flue gas path.
F Primary air control
It is used to regulate the primary air inflow. The primary air passes through
the grate of the firebox and fuels the combustion to determine its power
and speed. Rotate the control counterclockwise to reduce the air inflow.
On the contrary, rotate the control clockwise to increase the air inflow.
ATTENTION: When the appliance is operating the
temperature of the primary air control is very high, so
take care not to touch it. The glove provided must be
worn when handling it.
G Combustion secondary air levers
Controls the secondary air inflow which preheats as it passes through the
holes in the back of the combustion chamber and facilitates triggering the
second combustion. Shift one of the two levers to the left to reduce the air
inflow. Whereas to increase the inflow air shift it to the right.
ATTENTION: The temperature of the secondary air
levers is very hot while the appliance is operating, so
take care not to touch them. The glove provided must
be worn when handling them.
Smoke by-pass
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Thermorossi Vittoria at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Thermorossi Vittoria in the language / languages: English as an attachment in your email.

The manual is 3.74 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info