648212
20
Zoom out
Zoom in
Previous page
1/28
Next page
18
3) Connecting the device
- The device must be supplied with 230V, 50Hz.
- Mains connection must be ensured using the 3-wire cable factory fitte to the heater , through a
connecting box. In damp premises, such as bathrooms and kitchens, install the connecting box at
least 25cm from the ground..
- The installation must comply with local national regulation. If in doubt, ask the national Atlantic dis-
tributor.
- Ground connection is forbidden.
Do not connect the pilot wire (black) to ground.
- If power cable is damaged or too short, to avoid any danger it must be replaced by a qualified elec-
trician using special tools.
- If a heater pilots or is piloted by a 30mA differential (e.g. bathroom), the pilot wire supply must be
protected on this differential.
4) How to connect the mixed version to the water system ?
For the connection of hot water, the mixed version comprises 2 threaded ports 1/2 gas 15/21 F
Panel heater cable
Live=brown
Neutral=blue
LIVE
N
EUTRAL
Electricity
g
rid
Two possible cases
Pilot wire=Black
1st case: only one heater
2nd case: multiple heaters
The pilot wire end is insulated
a
nd not further connected
T
he pilot wire of all heaters in a
control group, up to a maximum
o
f 20 units with any one them used
as the Master, are connected
by a 1.0mm
2
220-240V insulated cable
WALL
CONNECTION
GROUND
CONNECTION
COVER
Threaded ports
1/2 GAS 15/21 F
WATER INLET
1/2 GAS 15/21 F
mini
122 maxi
115
mini525
mini200
mini259
195
446
80
MIDDLE OF THE DEVICE
WATER OUTLET
1/2 GAS 15/21 F
386
FRONT VIEW
SIDE VIEW
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Thermor TH5321705 - Riva 2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Thermor TH5321705 - Riva 2 in the language / languages: English, French as an attachment in your email.

The manual is 4,58 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info