8) Programming mode :
This device has a thermostat capable of receiving orders through its pilot wire. It recognizes the following commands:
- CONFORT (comfort) : Temperature set using the thumb-wheel w
- CONFORT 1 (comfort 1) : Temperature set using the thumb-wheel w -1°C
- CONFORT -2 (comfort 2) : Temperature set using the thumb-wheel w -2°C
- ECO : Temperature set using the thumb-wheel v
- HORS GEL (frost-free) : Room temperature maintained at approximately 7°C
- ARRET (Off) : Immediate stoppage of the device (used for load-shedding).
To activate the programming mode set cursor u to
.
In this way, by connecting the pilot wire to a timer, you can program your Comfort and Economy temperature periods.
It is possible to connect several devices to one timer and, in this way, make energy savings.
NB: When there is no command given over the pilot wire, the device heats in the Comfort mode. HG and load-shedding
commands override the Economy and Comfort modes. On changing from the Comfort mode to the Economy mode,
the changeover time is approximately 12 seconds.
- There is no point in setting the unit to its maximum, the room temperature will not rise any faster.
- Switch the unit off by putting cursor u to
.
- Remember to lower the temperature f you go out for several hours.
If go out for : less than 2 hours, do not touch the controls.
from 2 hours to 24 hours, set the cursor u to
.
for more than 2 hours or during the summer, put the unit in Frost Free mode ( ).
If you have several units in the room, let them all operate at the same time, this will give a more uniform temperature
without increasing electricity consumption.
RECOMMANDATIONS FOR USE
WARNINGS
This appliance is not intended for use by young children or infirm persons without
supervision. Young children should be supervised to ansure that they do not play
with the appliance, lean against the front or insert objects or paper in it.
Do not totally or partially block the grilles on the front or inside of the appliance, as
this may cause overheating.
If the supply cord is damaged, it must be replaced by a service agent or similarly
qualified person in order to avoid a hazard (applies to units fitted with a supply cord
and plug).
Units fitted with a three core supply cord (brown, blue & black), must be directly
connected to fixed wiring by a licensed electrician.
All work on the interior of the appliance must be carried out by a licensed electrician.
To maintain performances of your unit, you should clean the upper and lower grilles of the unit about twice a year using
a vacuum cleaner or a brush.
Have a professional check the inside of the unit every five years.
Dirt may collect on the grille of the unit if the atmosphere is polluted. This phenomenon is due to the poor quality of
the ambient air. In this case, it is recommended to check that the room is well ventilated (ventilation, air inlet, etc.),
and that the air is clean. The unit will not be replaced under the guarantee because of this type of dirt.
The unit casing should be cleaned with a damp cloth, never use abrasive products.
MAINTENANCE
080214_CEETvariation_ang.PMD 07/09/05, 14:063
27


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Thermor TH5271120 - 200 VAHB at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Thermor TH5271120 - 200 VAHB in the language / languages: English, German, Dutch, French, Polish as an attachment in your email.

The manual is 2,48 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info