24
Malfunction
 Possible cause Troubleshooting
Low output at the
hot water faucet.
 
is cloggeg.
 Scaling of the water heater.
 
 Descale water heater.
Continuous water
leaking from the
safety unit outside
heating periods.
 Damaged or dirty safety
valve.
 Pressure of the main water
supply is too high.
 Replace the safety unit.
 Check if the pressure at the
water meter outlet does not
exceed 0.5 MPa (5 bar), other-
wise install a pressure reducing
device set at 0.3 MPa ()
at the beginning of the general
water system.
Electric heating
element does not
work.
 Mechanical thermostat is
󰀨
 Electric heating element is
defective.
 Reset the fuse of the thermo-
stat at the level of the resistant
steatite.
 Replace resistor/electric heat-
ing element.
Condensate over-
stagnant


)
 Condensate drainage
obstructed.
 Clean.
Odour 
unit

the safety unit.


Steam release
󰀨
 Electric heating element is
continuously switched on.
 󰀨
notify the heating engineer.
Heat pump oper-
󰀨
peak hours.
 Failed to achieve nominal
temperature.
 Evaporator extremely
contaminated.
 See operating principle mode:
The AUTO mode allows for
󰀨
hours.
 Clean evaporator.
26


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Thermor Aeromax Split 2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Thermor Aeromax Split 2 in the language / languages: English, German, Dutch, French, Italian, Polish, Portuguese, Spanish as an attachment in your email.

The manual is 30.92 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info