600941
32
Zoom out
Zoom in
Previous page
1/37
Next page
32
superior position with regards to heating and the maintenance of the set temperature always proceeds without
time limits (with the exception of the MRC signal). Shall the temperature in the storage tank fall below the set
value, the boiler system three-way valve position is set preferentially and the boiler water heats up the external
indirect heating DHW storage tank. The DHW preparation can be deactivated by setting the boiler in the
SLEEP mode. If the operation mode is set after the termination of the MRC signal, the DHW preparation
becomes interrupted.
Connections of the storage tank and the three-way valve are shown in the electric diagram.
Connection diagram of an electric boiler with indirect heating storage tank for informational
purposes
T1
MV
AB
B
A
DHW
T
Electric boiler
Indirect heating
storage tank
Thermostat or DHW NTC sensor
MV – valve servomotor
AB – heating water inlet from the boiler
A – heating water outlet to the storage tank
B – heating water outlet to the heating circuit
T1 – storage tank thermostat
T – NTC sensor of the storage tank
TUV – DHW outlet
32


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Thermona THERM EL 45 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Thermona THERM EL 45 in the language / languages: English as an attachment in your email.

The manual is 0,87 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info