11. INSTALLING THE UNIT (first read “General instructions”)
Please note: Before placing the unit, we recommend you first read Chapter 7
“Concentric flue system” on page 11.
11.1 Connection to the gas pipes (see page 24 for details)
You can determine where the gas pipes will be placed, dependent on the layout. Ensure control equipment is not
twisted during installation and there is no excessive tension. Accessibility of various connection points in relation to
components need to be maintained. After installation, check the connections for tightness in relation to gas. Use a
1/2“ gas tap with connection. Ensure the gas pipes are dirt-free and sand-free, and gas and combustion prod-
ucts from various parts and functioning is correct. The gas connection should only be undertaken when the elec-
tricity supply is disconnected. This prevents any damage occurring to the gas control equipment.
11.2 Preparation and installation of the unit
Remove the packaging and check the unit for possible damage.
Place the unit at the installation location
Please note: place the unit on a stable surface.
Please note: Do not place the unit on its back or on its side!
The front window should now be removed in order to take the additional parts out of the unit.
Remove the decoration strip (See Page 27-A) after this loosen the 2 “Z” profiles (See Page 27-B) at the top
and bottom by loosen the 4 screws (leave profiles).
With the supplied suction cup you can remove the windows easily. Place the suction cup on the windows and
move it Carefully upwards, then Carefully and slowly pull the bottom of the window towards you. Next,
lower the window and leave it in a safe place where it cannot be broken or damaged.
Please note: the window is very fragile. You should therefore be very careful when (re) installing the
Window.
Next, take the packed components out of the unit and check to make sure they are not damaged or broken.
installation situation
Situate the unit (see page 28 as an example situation) in your chosen installation location . At the rear and the
sides, the unit must have at least 25 mm clearance from fireproof built-in materials. Install the supplied con-
vection grilles at least 50 cm below the ceiling on the appropriate wall. A lowered ceiling inside the whole
structure could be a possible solution in the event of a situation with a visual obstruction. For an assembly
with masonry, a lintel (see page 28-A) should be placed. It is also possible to build the fireplace using fire-
proof plate (See Page 28 fig.3)
The legs of the unit can be adjusted, and if necessary shortened, see also dimensional drawings. The adjustable
feet allow fine adjustments (levelling) to be made.
Gas pipe, thermocouple and ignition cables have been placed in coils under the unit. Cut the binders and
CAREFULLY unroll the various lines and cables to the position where the gas control cassette is to be
placed.
Fixing to the wall is effected by means of adjustable wall brackets at the backside of the unit. Fastening mate-
rials are not included.
Now determine the installation and assembly of the CC ducts and accessories. Please refer to Chapter 7.
CONCENTRIC FLUE SYSTEM CC” on Page 10 and “Table of concentric pathways “ on Page 26.
Build the control unit (B) to the your chosen installation location.
Please note:
The distance between the gas cassette / control cabinet and the unit will be determined by the cable /
thermocouple / line lengths from the control cabinet to the pilot burner and main burner.
The max. distance is approximately 1000 mm. The pipes, cables and/or couplings etc. should only be
connected when the electricity supply is off.
11.3 Fitting the ceramic log inset (see page 32 to 33)
* After servicing care must be taken that the burner is properly placed back Attn injector. Incorrectly installed
ceramic wood blocks and glowing material may have a significant influence on the fire image and the
burning effect.
* Spread both sides of the burner on the grill the black worm-like grains in bag A.
* Fill the burner, as indicated by the worm-like particles from the bag B.
* Place the ceramic wood blocks in the correct order as shown on Pag. 32 and 33.
* Glowing embers can be placed here and there as decoration. See Page 33 for example
MAKE SURE THE PILOT LIGHT REMAINS UNOBSTRUCTED!
23


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Thermocet Trimline Quadro 46 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Thermocet Trimline Quadro 46 in the language / languages: English as an attachment in your email.

The manual is 1,83 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Thermocet Trimline Quadro 46

Thermocet Trimline Quadro 46 Installation Guide - English - 85 pages

Thermocet Trimline Quadro 46 User Manual - English - 85 pages

Thermocet Trimline Quadro 46 Installation Guide - German - 85 pages

Thermocet Trimline Quadro 46 User Manual - German - 85 pages

Thermocet Trimline Quadro 46 Installation Guide - Dutch - 85 pages

Thermocet Trimline Quadro 46 User Manual - Dutch - 85 pages

Thermocet Trimline Quadro 46 Usermanual and installation guide - Dutch - 34 pages

Thermocet Trimline Quadro 46 Installation Guide - Danish - 85 pages

Thermocet Trimline Quadro 46 User Manual - Danish - 85 pages

Thermocet Trimline Quadro 46 Installation Guide - French - 85 pages

Thermocet Trimline Quadro 46 User Manual - French - 85 pages

Thermocet Trimline Quadro 46 Installation Guide - Spanish - 85 pages

Thermocet Trimline Quadro 46 User Manual - Spanish - 85 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info