Thermostatic Mode
The room temperature is measured and compared to the set temperature.
The flame height is then automatically adjusted to achieve the set temperature
Program Mode
Programs 1 and 2, each can be programmed to go ON and OFF at specific times
at a set temperature.
Eco Mode
Flame height modulates between high and low depending on room temperature
in relation to set temperature. lf the room temperature is lower than set
temperature, the flame height stays on high longer. lf the room temperature is
higher than set temperature, the flame height stays on low longer.
Once cycle takes approx. 40 min.
MANUAL MODE (HANDSET)
TO TURN ON FIRE
Handset One-Button Operation
(Default Setting)
* Press button until two short beeps and a blinking series of lines confirms
the start sequence has begun; release button.
* Main gas flows once pilot ignition is confirmed.
* Handset automatically goes into Manual Mode after main burner ignition
(CSA version, CE version).
NOTICE
BEFORE OPERATING
1. Make sure MANUAL knob on the GV60 Valve is in the ON, full counter clockwise position.
2. Place the ON/OFF switch (if equipped) in the "I" (ON position).
NOTICE
Change from one-button to two-button ignition operation by pressing and holding button for 16 sec.
immediately after installing batteries. ON is displayed and 1 is flashing.
When change is complete 1 changes to 2.
WARNING
When pilot ignition is confirmed, motor turns automatically to maximum flame height.
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Thermocet Trimline 85 R - 1050 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Thermocet Trimline 85 R - 1050 in the language / languages: English as an attachment in your email.

The manual is 4,38 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Thermocet Trimline 85 R - 1050

Thermocet Trimline 85 R - 1050 Usermanual and installation guide - Dutch - 43 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info