532678
19
Zoom out
Zoom in
Previous page
1/39
Next page
Pag.19
No ACTIE Mogelijk probleem/
oorzaak
Oplossing
6.
NEE
Weerstand in thermokop-
pel circuit te hoog.
Controleer kabels en verbindingen in
thermokoppel circuit.
Magneet spoel valt
uit(hoorbare klik)
Thermokoppel niet warm
genoeg.
Controleer of waakvlam goed op
thermokoppel staat, en stel zo nodig
waakvlam juist in.
Motor draait naar hoofd-
branderstand en waak-
vlam blijft branden.
Lage thermokoppelspan-
ning.
Controleer verbindingen en vervang
zo nodig thermokoppel. Draai de
verbindingen niet te vast aan!
Kortsluiting door bescha-
digde thermokoppel tip.
Vervang thermokoppel, draai de ver-
bindingen niet te vast aan!
NEE
Ontstekings procedure
stopt. Geen reactie meer
bij gebruik afstandbedie-
ning ( ontvanger reageert
niet meer).
Druk op RESET knop, zie instructie
Maak massakabel tussen waakvlam-
brander en gasregelklep.
OK
Vonkkabel niet oprollen
Kort ontsteekkabel in indien moge-
lijk.
7.
Hoofdbrander gaat aan.
NEE
Knop handmatige bedie-
ning gasregelklep op MAN
positie.
Knop naar ON positie draaien.
OK
8.
Hoofdbrander blijft aan.
NEE
Teveel/te weinig luchtstro-
ming/trek langs waakvlam,
waait uit of verstikt.
Controleer of restrictieplaat in toestel
juist is toegepast, zie instructie.
Slechte afvoersituatie, controleer
juistheid traject en de verbindingen.
OK
9.
Magneetspoel valt uit,
terwijl motor draait.
3x Piep signaal
NEE
Ontvanger batterijen
slecht.
Vervang batterijen, 1,5V AA Alkali-
ne kwaliteit!
Systeem kan worden wor-
den uitgeschakeld middels
afstandbediening
NEE
Systeem kan worden
uitgeschakeld door
ON/OFF schakelaar
NEE
Kortsluiting tussen TC en
SW kabel.
Controleer verbindingen bij onder-
breker.
JA
JA
OK OK
Vervang gasregelklep
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Thermocet Trimline 100 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Thermocet Trimline 100 in the language / languages: Dutch as an attachment in your email.

The manual is 6,27 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Thermocet Trimline 100

Thermocet Trimline 100 Usermanual and installation guide - English - 41 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info