659027
11
Zoom out
Zoom in
Previous page
1/125
Next page
Page.10
GASTYPE G20/G25 G30/31
PRESSURE 20//20-25 30//29-37//30-50
COUNTRY
NL/NO/DK/ES/PT/DE/IE/GB/BE/FR/IT/AT/
LV/SI/SK/EE/HU/LT
NL/NO/DK/DE/ES/PT/IE/GB/BE/FR/AT/LV/
SI/EE/HU/LT/PL/CY/MT/IT
CATEGORY I2l/I2ELL/I2H/I2E/I2E+ I3B/P/I3+
PRIMAIRY AIR 2xø8.5/1xø7 3XØ16
PRE PRESSURE MBAR 20/20-25 Mbar 30/37 Mbar
BURNERPRESSURE HIGH MBAR 11/13,7 26,2/33,6
BURNERPRESSURE LOW MBAR 7,1/7,0 11,1/14,6
INJECTOR SIZE Ø MM 2x2,5 2x1,45
INJ. PILOTBURNER CODE 51 30
LOWSETTING SIZE MM 2,20 1,80
LOAD Hs KW 15,5/14,6 15,2/15
LOAD Hi KW 14/13,1 13,9/13,8
CONSUMPTION M³/h 1,48/1,62 0,43/0,55
NOM.OUTPUT kW 12/11 11,7/11
1048 (170)
1139 / 1149 (140/140 tunnel)
GASTYPE G20/25 G30/31
PRESSURE 20//20-25 30//29-37//30-50
COUNTRY
NL/NO/DK/DE/ES/PT/IE/GB/BE/FR/AT/SI/
HU/PL/CY/MT/IT/CH/CZ/SK/SI
NL/NO/DK/DE/ES/PT/IE/GB/BE/FR/AT/SI/
HU/PL/CY/MT/IT/CH/CZ/SK/SI
CATEGORY I2H//I2E+//I2E-I2ELL//I2L I3B/P//I3+//I3P
PRIMAIRY AIR 2xø7,5mm/2xø4mm 3xø16mm
PRE PRESSURE MBAR 20//20-25 30//29-37//30-50
BURNERPRESSURE HIGH MBAR 14,3//17,8 24,6//24,6-30,4//24,6
BURNERPRESSURE LOW MBAR 13,2//16,6 11,8//11,8//14,4
INJECTOR SIZE Ø MM 2xø2,3mm 2xø1,45
INJ. PILOTBURNER CODE 51 30
LOWSETTING SIZE MM 2,2 1,3
LOAD Hs KW 16,1//14,3 14,3//14,3-14,2//13,1
LOAD Hi KW 14,5/12,8 13,2//13,2-13//12
CONSUMPTION M³/h 1,53//1,58 0,41//0,41-0,53//0,49
NOM.OUTPUT kW 12/10,7 8,8//8,8//10,8
Appliance has NoX Class 5
AT I2H, I3B/P BE I2E+, I3+ DK I2H, I3B/P DE I2ELL, I3B/P
FI I2H, I3B/P FR I2E+, I3+ GR I2H, I3B/P GB I2H, I3+
IS I3B/P IE I2H, I3+ IT I2H, I3+ LU I2E, I3B/P
NL I2L, I3B/P NO I3B/P PT I2H, I3+ ES I2H, I3+
SE I2H, I3B/P CY I3B/P, I3+ EE I2H, I3B/P LT I2H, I3B/P
LV I2H, I3B/P MT I3B/P HU I2H, I3B/P PL I3B/P
SI I2H, I3B/P SK I2H TR I2H, I3B/P
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Thermocet Trimline 100 DB Front - 1136 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Thermocet Trimline 100 DB Front - 1136 in the language / languages: English, German, Dutch, Danish, French, Spanish as an attachment in your email.

The manual is 6,18 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Thermocet Trimline 100 DB Front - 1136

Thermocet Trimline 100 DB Front - 1136 Installation Guide - Dutch - 27 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info