9. OPERATING INSTRUCTIONS FOR THE DUNGS AB COMBINATION
GAS REGULATOR
This regulator is fitted with a complete infra-red control system. This means that you can ignite the unit, smoothly
adjust the flame height and extinguish the unit using the remote control.
9.1 Infra-red remote control and its operation
The infra-red remote control allows you to comfortably control
the AB system. When in direct line of sight with the infra-red
receiver, the remote control has a range of approximately 15m
To start the system, press the buttons “ON” and “OFF” together
for at least 3 seconds. The start-up process is indicated by a se-
ries of three short tones. After the flame has lit, it can be in-
creased to the maximum height by pressing the “UP” button.
Pressing the “DOWN” button reduces the flame to its minimum
height. Pressing the “OFF” button for at least one second
switches off the system and places the unit in “Stand By" mode.
In the event of a fault in the unit (a red LED lamp lights on the
receiver), the system can be reset by pressing the “ON” and “OFF” buttons at the same time for at least 3 seconds
which will return it to the “STAND BY” mode. The “Automod” button starts automated adjustment of the system.
When automated adjustment is selected, the power of the unit automatically reduces from approximately 80% to
20% and then increase from 20% back to 80% again within a set time interval. This function can be stopped by
pressing the “Automod” button again or by pressing the “UP” or “DOWN” buttons. Depending on the individual
specification of the unit, the FOCContact knob can be used. Pressing the button engages a transistor that enables
external units with their own power supply to be switched on or off.
9.2 Igniting the gas fire.
Open the gas shut-off tap that has been fitted in the gas pipe leading to the unit. Now follow the steps described
above in “Infra-red remote control and its operation.”
Systeem "OFF"
AUTO mod / Aan / Uit
FOCContact / Aan / Uit
Led
Vlamhoogte / "UP"
Vlamhoogte / "DOWN"
Systeem "ON"
9.3 Basic system components (See page 22)
1: Modu box 4: Gas control block
2: Transformer (24 V) 5: Remote control
3: IR receiver 6: Wire harness
9.4 Connection to the gas regulation block wiring
1: Blue / Blue
2: Black / Black
3: Red / Red
4: Yellow-green
9.5 Adjusting the Gas regulation block (See adjustment values
on pages 23 and 24)
Setting the flow rate - Low setting
A Connect manometer to pressure measuring point (9)
B Ignite the fire
C Set the flow rate by turning adjustment screw 11 with a screw
driver.
- turn clockwise, to reduce "-"
- turn anti-clockwise, to increase "+"
Setting the flow rate - High setting
A Connect manometer to pressure measuring point (9)
B Ignite the fire
D Set the flow rate by turning adjustment screw 12 with a screw
driver.
- turn clockwise, to reduce "-"
- turn anti-clockwise, to increase "+"
1 2 3
9
11
12
13
mBar
- +
1 2 3
5
4
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Thermocet Transparente 73 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Thermocet Transparente 73 in the language / languages: English as an attachment in your email.

The manual is 1,84 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Thermocet Transparente 73

Thermocet Transparente 73 Usermanual and installation guide - Dutch - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info