606775
48
Zoom out
Zoom in
Previous page
1/71
Next page
TR 648 top2 RC / -DCF KNX 8-channel 365 day time switches
Status: March 14 (Subject to change) Page 48 of 71
4.2.4 Important parameter settings
Standard or customer-defined parameter settings apply for unlisted parameters.
Table 29: TR 648 top2 KNX
Parameter page
Parameter
Setting
General
Activate time switch channel
C1
Yes
Switching channel C1
Telegram type C1.1
HVAC operating mode
With clock
ON
standby
With clock
OFF
night-time temperature
reduction
Program example for the TR 648 top2 KNX: Channel 1, 7:30 ON, 17:30 OFF, Monday to
Friday.
Table 30: RAM 713 S
Parameter page
Parameter
Setting
Settings
Function of external interface
active
Operating mode
Objects for determining the
operating mode
New: Operating mode,
presence, window status
Operating mode after reset
standby
Type of presence sensor
Presence detector
Cyclical transmission of
current operating mode
Not cyclical, only in the event
of change
Input 1
Function of E1
Switching
Reaction to closing the
contact
ON (OFF*)
Reaction to opening the
contact
OFF(ON*)
Send cyclically
Every 5 minutes
* Depending on type of window contact. The details in brackets refer to the following case:
Window closed contact closed.
48


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Theben TR 648 top2 RC-DCF KNX - 6489210 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Theben TR 648 top2 RC-DCF KNX - 6489210 in the language / languages: English as an attachment in your email.

The manual is 3,61 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Theben TR 648 top2 RC-DCF KNX - 6489210

Theben TR 648 top2 RC-DCF KNX - 6489210 User Manual - English - 36 pages

Theben TR 648 top2 RC-DCF KNX - 6489210 User Manual - German - 36 pages

Theben TR 648 top2 RC-DCF KNX - 6489210 User Manual - German - 72 pages

Theben TR 648 top2 RC-DCF KNX - 6489210 User Manual - Dutch - 36 pages

Theben TR 648 top2 RC-DCF KNX - 6489210 User Manual - Dutch - 64 pages

Theben TR 648 top2 RC-DCF KNX - 6489210 User Manual - French - 36 pages

Theben TR 648 top2 RC-DCF KNX - 6489210 User Manual - French - 64 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info