3.3.2.2 The "Date and time" parameter page
Table 13
Designation
Values
Description
Mode of operation of
object, time and date
send time and date
If "send' is selected, the clock can send
the current time and date to the bus
cyclically and on request.
receive time and date
If "receive" is selected, the clock can
be reset via external time and date
telegrams.
Parameter for send time and date
send time and date
on request
every minute
every hour
every day at midnight and at
summer/winter changeover
Every day at 00:02 and at
summer/winter changeover
Setting, when for example how often
time and date should be sent.
Note:
Sending can be initiated at anytime via
the "time query' object.
Type of antenna
None
GPS (only 6489212)
DCF 77
The exact time is acquired via an
external receiver module.
Parameter for receiving time and date
Format of time and date
telegrams
standard (DPT 10.001 + DPT
11.001)
Time and date received separately at
objects 0 and 1.
data point Date Time (8 Byte,
DPT 19.001)
Receive time and date together as an 8
byte telegram on object 6.
Send time request
Do not send
every hour
every 2 hours
every 3 hours
every 6 hours
every 12 hours
If GPS or DCF modules are not used:
How often should a time query be sent
to the bus?
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Theben TR 648 top2 RC-DCF KNX - 6489210 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Theben TR 648 top2 RC-DCF KNX - 6489210 in the language / languages: English as an attachment in your email.

The manual is 3,61 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Theben TR 648 top2 RC-DCF KNX - 6489210

Theben TR 648 top2 RC-DCF KNX - 6489210 User Manual - English - 36 pages

Theben TR 648 top2 RC-DCF KNX - 6489210 User Manual - German - 36 pages

Theben TR 648 top2 RC-DCF KNX - 6489210 User Manual - German - 72 pages

Theben TR 648 top2 RC-DCF KNX - 6489210 User Manual - Dutch - 36 pages

Theben TR 648 top2 RC-DCF KNX - 6489210 User Manual - Dutch - 64 pages

Theben TR 648 top2 RC-DCF KNX - 6489210 User Manual - French - 36 pages

Theben TR 648 top2 RC-DCF KNX - 6489210 User Manual - French - 64 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info