84
13.0 Tips and additional possibilities
1. Priority program with random switching
Possibility for starting a random program automatically during public or
annual holiday times.
1. Program weekly program with the desired ON and OFF switching times and
priority sequence P1 .. P9 (Chapter 8.1)
2. Specifity the time period for the weekly program (Chapter 8.2).
3. Activate random program once manually (Chapter 6.7).
2. Special program for holidays
Procedurally during holidays to switch ON and OFF connected units at diffe-
rent times:
1. Program your desired holiday program. The ON and OFF switching times
must occur daily. A priority sequence P1..P9 must be assigned to the swit-
ching times (Chapter 8.1).
2. Specifity the time period for the weekly program
e.g. only for the 1st May➔ begin 01.05 finish 01.05 (Chapter 8.2).
3. Pulse program for time delayed switch-ONs
A switch-ON time e.g. at 7.0 and 10 secs can be achieved by:
1. programming a switch-ON time e.g. 7
00
ON (o) (Chapter 7.1)
2. Additional pulse program (Chapter 7.4) with same switch-ON time.
1. Switch-ON time e.g. 7
00
o
2. Additionally at 7
00
pulse OFF (p) for the duration
of 10 secs
3. Effective at 7
00
10 secs switch ON
Note: After a time adjustment, only pulses, which are programmed at
least 1 minute after the time adjustment, are carried out.
4. Pulse program for time delayed switch-OFF
A switch-OFF time e.g. at 8.0 and 10 secs. can be achieved by:
1. Programming a switch-OFF time eg.g. 8
00
(Chapter 7.1)
2. Additional programming of a simultaneous pulse switching time of 10 secs.
duration.
1. Switch-OFF time e.g. 8
00
OFF p
2. Additional pulse ON (o) at 8
00
for
10 secs duration
3. Effective at 8
00
10 secs.
switch OFF.
Note: After time adjustment, only pulses, which are programmed at