Bedienungsanleitung 1
Uhrenthermostat
Operating instructions 16
Clock thermostat
Mode d’emploi 31
Thermostat à horloge
Instrucciones de servicio 46
Cronotermostato
Istruzioni per l’uso 61
Cronotermostato
Gebruiksaanwijzing 76
Klokthermostaat
RAM 811 top RAM 813 top RAM 818 top RAM 820 top RAM 366 top
RAMSES 831 top
RAMSES 832 top
310 926 03
TR 610 top
Table of Contents
1 Designated Use .................................................................... 15
2 Safety Instructions............................................................... 15
3 Description and Mounting................................................... 16
3.1 DeviceOverview....................................................................16
3.2 MountingandElectricalConnection.......................................17
4 Installation and Operation................................................... 18
4.1 Carryingouta Reset..............................................................18
4.2 InsertingorExchangingBatteries(onlyRAMSES®811 top)18
4.3 SelectingtheLanguage.........................................................18
4.4 SettingtheTime / Date..........................................................18
4.5 SelectingtheTemperatureProfile..........................................19
4.6 CheckingCurrentRoomTemperatureandSettings-
InfoButton..............................................................................19
4.7 TemporarilyChangingtheTargetTemperature.....................20
4.8 EarlyCancellation,Checkor Clearanceofthe
HolidayProgram....................................................................20
4.9 Party/ Eco Program...............................................................21
5 Programming........................................................................ 21
5.1 SettingtheHoliday Program..................................................21
5.2 ChangingtheSettingsforTargetTemperatures....................22
5.3 ProgramP3............................................................................22
5.4 ServiceSettings.....................................................................25
5.5 Time/DateandSummer/WinterTime.....................................27
6 Maintenance and Repair...................................................... 28
7 Disposal ................................................................................ 28
7.1 DisposalofBatteries..............................................................28
7.2 Disposalofthe Device...........................................................28
8 Technical Data...................................................................... 28
1DesignatedUse
TheRAMSES®811/812 top isa digitalclock thermostatforcontrol-
lingtheroomtemperature.
TheroomthermostatRAMSES®811/812 top isintendedfortime-
androomtemperature-dependentonandoffswitchingofanelectrical
loadwitha maximumcurrentconsumptionof6 A, suchasa circula-
tionpump,aburnerora motor mixingvalve. It must onlybeusedin
dryroomswithimpuritiesthatareusualforflatsorhouses.
Designatedusealsoincludesadherencetotheoperatingandmount-
inginstructions.Anyotherusageis not allowed. Themanufacturer
cannotbeheldliablefordamagesresultingfromthis.
2 Safety Instructions
Theconnectionandinstallationofelectricaldevicesmust
onlybecarriedoutbya qualifiedtechnician.
Thenationalregulationsandrespectivesafetyinstruc-
tionsaretobe observed.
Interferencesandchangestothedevicewill lead tocan-
cellationofthewarranty.
Table of Contents
1 Designated Use. . …………………………...…….……………..16
2 Safety Instructions. . …………………………………………....16
3 Description and Mounting…………………………………… . 17
3.1 Device Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
3.2 Mounting and Electrical Connection. . . . . . . . . . . . . . . . . . . . . . . . . . . 18
4 Installation and Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
4.1 Carrying out a Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
4.2 Inserting or Exchanging Batteries (only RAMSES®831 top) . . . . . . 19
4.3 Selecting the Language. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
4.4 Setting the Time / Date . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
4.5 Selecting the Temperature Profile . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
4.6 Checking Current Room Temperature and Settings -
Info Button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
4.7 Temporarily Changing the Target Temperature . . . . . . . . . . . . . . . . . . . 21
4.8 Early Cancellation, Check or Clearance of the
Holiday Program . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
4.9 Party / Eco Program . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
5 Programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
5.1 Setting the Holiday Program . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
5.2 Changing the Settings for Target Temperatures . . . . . . . . . . . . . . . . . . 23
5.3 Program P1, P2, P3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
5.4 Service Settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
5.5 Time / Date and Summer / Winter Time . . . . . . . . . . . . . . . . . . . . . . . . 29
6 Maintenance and Repair. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
7 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
7.1 Disposal of Batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
7.2 Disposal of the Device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
8 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
1 Designated Use
The RAMSES®831/832 top is a digital clock thermostat for controlling the
room temperature.
The room thermostat RAMSES®831/832 top is intended for time and room
temperature-dependent on and off switching of an electrical load with a maxi-
mum current consumption of 6 A, such as a circulation pump, a burner or a
motor mixing valve. It must only be used in dry rooms with impurities that are
usual for flats or houses.
Designated use also includes adherence to the operating and mounting instruc-
tions.Any other usage is not allowed. The manufacturer cannot be held liable for
damages resulting from this.
2 Safety Instructions
The connection and installation of electrical devices must only be
carried out by a qualified technician.
The national regulations and respective safety instructions are to
be observed.
Interferences and changes to the device will lead to cancellation
of the warranty.
16
ENGLISH
3 Description and Mounting
3.1 Device Overview
Iconbarfordisplayofthe
programminglevel(rotaryswitch
positionMENU)
Changebuttons+/-
Rotaryswitchfor program selection
Button OK (confirmationofsettings/
selectionorprogramming)
Button ESC (cancellationof
programmingentries)
Info buttonforcheckingthe settings
Batterycompartment
(onlyRAMSES®811 top)
Toopen,pulltowardsthefront.
Hinged cover
Displayofthedayofweek
(1=Monday,2= Tuesdayetc.)
Multifunctionaldisplay,e.g.
"Roomtemperature20.0°C"
Display PARTY or
ECOprogramactive
Displayforbatteriesto be replaced
(onlyRAMSES®811 top)
Displayoftheswitch phases
RESET button
3 Description and Mounting
3.1 Device Overview
Hinged cover
Display of the day of week
(1 = Monday, 2 = Tuesday etc.)
Multifunctional display, e.g.
“Room temperature 20.O˚C”
Display PARTY or
ECO program active
Display for batteries to be replaced
(only RAMSES®831 top)
Display of the switch phases
RESET button
Icon bar for display of the
programming level (rotary switch position
MENU)
Change buttons +/-
Rotary switch for program selection
Button OK (confirmation of settings/ selec-
tion or programming )
Button ESC (cancellation of
programming entries)
Info button for checking the settings
Battery compartment
(only RAMSES®831 top)
To open pull towards the front.
17 ENGLISH
3.2 Mounting and Electrical Connection
3.2.1 Connection examples RAMSES®811 top
3.2.2 Connection examples RAMSES®812 top
Loadconnection
terminals Connectionterminalsmains230V
OnlyRAMSES®812 top
T1
T2
L
N
Controlofaburner
Controlviathe
circulationpumpor
storage-/hot-air
heating
Controlofamotor
mixingvalve
Controlviathe
circulation pump or
storage-/hot-air
heating
3.2 Mounting and Electrical Connection
Connection terminals mains 230 V
Only RAMSES®832 top
3.2.2 Connection examples RAMSES®832 top
Control of a motor
mixing valve
Control via the
circulation pump or
storage-/hot-air
heating
3.2.1 Connection examples RAMSES®831 top
Control of a burner
Control via the
circulation pump or
storage-/hot-air
heating
T1
T2
L
N
18
ENGLISH
4 Installation and Operation
For installation of
RAMSES®811/812 top
,follow thesections 4.1 to
4.5.
4.1 Carrying out a Reset
Afterhavingconnectedthepowersupplyorhavinginsertedthebat-
teries(whenexceedingthebatterychangepowerreserveof10min.),
youmustcarryoutaReset.Forthispurpose,openthehingedcover,
andpresswithapointedobjectontheReset buttonwhichisrecessed
inthecase(seefigurebelow).
4.2 Inserting or Exchanging Batteries
(only RAMSES®811 top)
Onlyuse1.5VbatteriesofthetypeAA,Alkaline.Replacethebatter-
iesevery1.5years.Alwaysreplacebothbatteries.
Wheninserting,makesurethebatteriesarecorrectlypolarised(see
figure).
Whentheinsertedbatteriesaredischarged,thisis indicatedin the
displaybytheflashingbatteryicon.Seefigureonpage16.
4.3 Selecting the Language
Note: Thelanguagecanalsobechangedinthe"Service"menu(see
page25).
4.4 Setting the Time / Date
WiththeESC button you can alwaysreturntothepreviousprogram-
mingstepinordertoadjust a setting.
Resetbutton
Pullthe battery
compartment
covertowards
thefront.
1. Thedisplayautomaticallyshowsthe selected languageafter
Reset.
2. Selectyourlanguagewiththebuttons
or .Theavailablelanguagesare
displayedoneaftertheother.Confirm
withthe OK button.
3. Thedisplayautomaticallyswitchesto thetimesetting.
1. Thedisplayshowsthetimesetting.
2. Setthecurrenttimewiththebuttons
and :
SetthehourandconfirmwiththeOK
button.
Settheminutesandconfirmwiththe
OK button.
Deutsch
English
Francais
Italiano
Espanol
NL
OK
Hour
0: 00
OK
Hour
15:00
OK
Minute
15:34
4 Installation and Operation
For installation of RAMSES®831/832 top, follow the sections
4.1 to 4.5.
4.1 Carrying out a Reset
After having connected the power supply or having inserted the batteries (when
exceeding the battery change power reserve of 10 min), you must carry out a
Reset. For this purpose, open the hinged cover, and press with a pointed object
on the Reset button which is recessed in the case (see figure below).
4.2 Inserting or Exchanging Batteries
(only RAMSES®831 top)
Only use 1.5 V batteries of the type AA, Alkaline. Replace the batteries every 1.5
years.Always replace both batteries.
When inserting, make sure the batteries are correctly polarised (see figure).
When the inserted batteries are discharged, this is indicated in the display by the
flashing battery icon. See figure in chap. 3.1.
Reset button
Pull the battery
compartment
cover towards
the front.
4.3 Selecting the Language
1. The display automatically shows the selected language after Reset.
2. Select your language with the buttons
or . The available languages are
displayed one after the other. Confirm
with the OK button.
3. The display automatically switches to the time setting.
Note: The language can also be changed in the “Service” menu (see chap. 5.4).
4.4 Setting the Time / Date
With the ESC button you can always return to the previous programmming step
in order to adjust a setting.
1. The display shows the time setting.
2. Set the current time with the buttons
and :
Set the hour and confirm with the OK
button.
Set the minutes and confirm with the
OK button.
nederlands
francais
english
deutsch
italiano
espanol
portugues
19 ENGLISH
Note: Thetimeanddate canalsobechangedinthe"Service"menu
(seepage25).Thereyoucanalsosetthechangeoverfromwinterto
summertime.
4.5 Selecting the Temperature Profile
4.5.1 Program P1 (fixed program)
ComforttemperatureMo-Frfrom6a.m.10p.m.as
wellasSa-Sufrom7a.m.-11p.m.Inbetweenlow-
ertemperature.
4.5.2 Program P2 (fixed program)
ComforttemperatureMo-Frfrom 6-8a.m.andfrom4to10p.m.as
wellasSa-Sufrom7a.m. 11p.m.Inbetweenlowertemperature.
4.5.3 Program P3 (freely programmable)
TheprogramP3isanindividuallyprogrammabletemperatureprofile.
ProgramP3isnotprogrammedwhendelivered.Forprogramming
seepage22.
4.5.4 Permanent comfort
Theroomtemperatureispermanentlyregulatedtotheprogrammed
comforttemperature.Thereisnoreduction.
4.5.5 Permanent reduction
Theroomtemperatureispermanentlyregulatedtotheprogrammed
lowertemperature.
4.5.6 Antifreezing
Theroomthermostatonlycomesonwhentheroomtemperaturefalls
belowtheprogrammedantifreezetemperature.
4.6 Checking Current Room Temperature and
Settings - Info Button
WiththeInfo buttonyoucandisplaythecurrentroomtemperatureas
wellasall importantsettingsoftheprogramsetattherotaryswitch.
3. Thedisplaychangesautomaticallyto
thedatesetting.
Settheyear,monthanddate one
aftertheother.Confirmeach setting
withthe OK button.The display
changesautomatically.
4. Thedisplayautomaticallychangestothe set automaticmode,
e.g.displayofthetargettemperature.
OK
Year
2002
Month
04
OK
Day
09.04
OK
P2 P3
P1
MENU
1. PresstheInfo button.Thecurrentroomtemperatureisshownin
thedisplayforapprox. 3 seconds. In ordertocontinuewiththe
check,presstheInfo buttonagain.
2. Thiswayyoucancheckthe followinginformationoneafterthe
other:
- Roomtemperature
- Currentlyactive targettemperature
- Dateandtime
- Switchtimesofthesetprogram(onlyvisiblewithopened
hingedcover).Thefixedprogrammedtemperatureprofiles
andswitchtimes are described insection4.5.
3. The display changes automatically to
the date setting.
Set the year, month and date one
after the other. Confirm each setting
with the OK button. The display
changes automatically.
4. The display automatically changes to the set automatic mode,
e.g. display of the target temperature.
Note: The time and date can also be changed in the “Service” menu (see chap.
5.4). There you can also set the changeover from winter to summer time.
4.5 Selecting the Temperature Profile
4.5.1 Program P1 (freely selectable)
Comfort temperature Mon-Thu from 6.00 - 22.00 hrs and Fri
from 6.00 - 23.00 hrs; Sat 7.00 - 23.00 and Sun 7.00 - 22.00
hrs. Reduced temperature between.
4.5.2 Program P2 (freely selectable)
Comfort temperature Mon-Thu from 6.00 - 8.00 and 16.00 - 22.00 hrs and Fri from
6.00 - 8.00 and 16.00 - 23.00 hrs; Sat 7.00 - 23.00 and Sun 7.00 - 22.00 hrs.
Reduced temperature between.
4.5.3 Program P3 (freely selectable)
The program P3 is an individually programmable temperature profile. Program P3 is
not programmed when delivered. For programming
see chap. 5.
4.5.4 Permanent comfort (using Comfort + Reduced 1)
The room temperature is permanently regulated to the programmed comfort
temperature.There is no reduction.
4.5.5 Permanent reduction (using Comfort + Reduced 1)
The room temperature is permanently regulated to the programmed lower
temperature.
4.5.6 Antifreezing
The room thermostat only comes on when the room temperature falls below
the programmed antifreeze temperature.
4.6 Checking Current Room Temperature and
Settings - lnfo Button
With the lnfo button you can display the current room temperature as well as
all important settings of the program set at the rotary switch.
1. Press the Info button. The current room temperature is shown in
the display for approx. 3 seconds. In order to continue with the
check, press the lnfo button again.
2. This way you can check the following information one after the
other:
- Room temperature
- Currently active target temperature
- Date and time
- Set display type, (i.e. which information is shown in the
display, also see chap. 5.4.2).
20
ENGLISH
P2 P3
P1
MENU
3. Thecheckiscompleted.Thedisplayautomaticallyswitchesback
totheoriginalstate.
4.7 Temporarily Changing the Target
Temperature
Withthisfunction,youcantemporarilychangethetargettemperature
givenbytheprogram.Thechangedtargettemperatureisnotsaved
long-term.Itonlyremainssetuntilthenexttemperaturechangeofthe
program(e.g.fromcomfortto lowertemperature).
Note: Ifoneoftheprograms"Perm.comfort","Perm.lower"or"Frost"
isset,the temperaturechangeremainsuntiltheprogramchanges.
4.8 Early Cancellation, Check or Clearance of
the Holiday Program
Ifyouwant to cancel an activatedholidayprogramearly,youmust
cleartheholidayprogram.
Note: Thesettingoftheholidayprogramisdescribedinsection5.1
onpage21.
- Setdisplaytype,(i.e.which informationis shown inthe dis-
play,alsoseepage25).
1. Pressoneofthe buttons or .Thedisplayshowsthesettar-
gettemperature.
2. Changethetargettemperaturewiththebuttons or .
3. Afterapprox.3seconds,thedisplayautomaticallyswitchesback
toitsoriginalstate,andthe roomthermostatregulatestothe
changedtargettemperature.
1. Openthehingedcoverandturntherotaryswitchtothe MENU
setting.
2. Withthebuttons or , selecttheoption
Holiday
.Confirmwith
theOK button.
3. Withthebuttons or , select thedesiredoptionandconfirm
withthe OK button:
-
Check
:Byrepeatedpressingofthe OK button, you can check
allsettingsofthesavedholidayprogramoneaftertheother
(startorendtime,temperature).
-
Clear
:Bypressing the OK button,thesavedholidayprogram
iscleared.
Youcannowprogramanewholidayprogram(seesection5.1
onpage21)orsetthe desiredtemperatureprofile(automatic
program)attherotaryswitch(see section4.5 onpage19).
- Reset operating hours
3. The check is completed.The display automatically switches back
to the original state.
4.7 Temporarily Changing the Target
Temperature
With this function, you can temporarily change the target temperature given by
the program. The changed target temperature is not saved long-term. It only
remains set until the next temperature change of the program (e.g. from comfort
to lower temperature).
Note: If one of the programs “Perm. comfort”, “Perm. lower” or “Frost” is set,
the temperature change remains until the program changes.
1. Press one of the buttons or . The display shows the set
target temperature.
2. Change the target temperature with the buttons or .
3. After approx. 3 seconds, the display automatically switches back
to its original state, and the room thermostat regulates to the
changed target temperature.
4.8 Early Cancellation, Check or Clearance of
the Holiday Program
If you want to cancel an activated holiday program early, you must clear the
holiday program.
Note: The setting of the holiday program is described in section 5.1.
1. Open the hinged cover and turn the rotary switch to the MENU
setting.
2. With the buttons or , select the option holiday Confirm with
the OK button.
3. With the buttons or , select the desired option and confirm
with the OK button:
-check: By repeated pressing of the OK button, you can check
all settings of the saved holiday program one after the other
(start or end time, temperature).
-clear: By pressing the OK button, the saved holiday program
is cleared.
You can now program a new holiday program (see section 5.1) or
set the desired temperature profile (automatic program) at the
rotary switch (see section 4.5).
21 ENGLISH
4.9 Party / Eco Program
Withthe"Party/Eco"function,youcancancelthetemperatureprofile
ofthesetprogramforthenextfew hours(upto23hoursand50min-
utes).
4.9.1 Setting the Party / Eco Program
4.9.2 Early Cancellation of the Party / Eco Program
Inorderto cancelthe"Party / Eco"program,pressbothbuttons
and forapprox.2seconds,untilthedisplaychanges.Waitanother
3secondsuntilthedisplaychangesbackagain.TheParty/Ecopro-
gramiscancelled,andtheaddition"PARTY"or"ECO"disappears
fromthedisplay.
5 Programming
Note: TheP1andP2 programsarefixedprogramsexworks,and
cannotbechanged.
5.1 Setting the Holiday Program
Bysettingaholidayprogram,thetemperatureprofileofthe set auto-
maticprogramcanbecancelledforanyperiodoftime.
Note: With the ESC button, you can cancel the programming at any
time.
1. Pressbothbuttons and at the same timeforapprox.2sec-
onds.
2. Thedisplaychangesandshowsthetext
Period
and a flashing
clock.Within3seconds,pressoneofthebuttons or ,andset
thedesiredperiodinincrements of10minutes.
3. After 3seconds,thedisplaychangesandshowsthetext
Comfort
or
Lower
.Within3seconds,selectthe comfortor lower tempera-
turewiththebuttons or .
4. Thedisplaychangesautomaticallyafter3seconds.Thedisplay
showsthedesiredtargettemperaturewiththeaddition"PARTY"
(forcomforttemperature) or"ECO"(forlowertemperature).The
PartyorEcoprogramisactiveforthe setperiod.
1. Openthehingedcoverand turn the rotaryswitchtothe MENU
setting.
2. Withthebuttons or , select theentry
Holiday
.Confirm with
theOK button.
Note: Ifaholidayprogramis alreadysaved, you can chooseif
youwanttocheck or clear it. Inordertosavea newholidaypro-
gram,thealreadysavedholidayprogrammust be cleared.See
section4.8onpage20.
3. Ifnoholidayprogramhasbeensavedyet,setthestartandend
datenowwiththebuttons and .
Settheyear,month,dateandhourone aftertheother. Confirm
eachsettingwiththeOK button.Thedisplaychangesautomati-
cally.
Note: Theendtimemustnotbethesame asorearlierthanthe
starttime.Otherwisean errormessageis displayed:
Error
.The
holidayprogrammustthen be programmedagain.
4. Selectwhetheryouwantthecomfort,theloweror the antifreeze
temperatureforthesetperiod.Confirmwith the OK button.
4.9 Party / Eco Program
With the “Party / Eco” function, you can cancel the temperature profile of the
set program for the next few hours (up to 23 hours and 50 minutes).
4.9.1 Setting the Party / Eco Program
1. Press both buttons and at the same time for approx. 2
seconds.
2. The display changes and shows the text period and a flashing
clock. Within 3 seconds, press one of the buttons or , and
set the desired period in increments of 10 minutes.
3. After 3 seconds, the display changes and shows the text comfort
or lower. Within 3 seconds, select the comfort or lower temperature
with the buttons or .
4. The display changes automatically after 3 seconds. The display
shows the desired target temperature with the addition “PARTY”
(for comfort temperature) or “ECO” (for lower temperature). The
Party or Eco program is active for the set period.
4.9.2 Early Cancellation of the Party / Eco Program
In order to cancel the “Party / Eco” program, press both buttons and for
approx. 2 seconds, until the display changes. Wait another 3 seconds until the
display changes back again. The Party / Eco program is cancelled, and the addi-
tion “PARTY” or “ECO” disappears from the display.
5 Programming
Note: The programs P1, P2 and P3 are freely selectable.
5.1 Setting the Holiday Program
By setting a holiday program, the temperature profile of the set automatic
program can be cancelled for any period of time.
Note: With the ESC button, you can cancel the programming at
any time.
1. Open the hinged cover and turn the rotary switch to the MENU
setting.
2. With the buttons or , select the entry holiday. Confirm with
the OK button.
Note: If a holiday program is already saved, you can choose if
you want to check or clear it. In order to save a new holiday pro-
gram, the already saved holiday program must be cleared. See
section 4.8.
3. If no holiday program has been saved yet, set the start and end
date now with the buttons and .
Set the year, month, date and hour one after the other. Confirm
each setting with the OK button. The display changes automati-
cally.
Note: The end time must not be the same as or earlier than the
start time. Otherwise an error message is displayed: error. The
holiday program must then be programmed again.
4. Select whether you want the comfort, the lower or the antifreeze
temperature for thd set period. Confirm with the OK button.
22
ENGLISH
Hinweis: DasAbfragen,LöschenoderBeendeneinesFerienpro-
grammsistinAbschnitt4.8aufSeite6 beschrieben.
5.2 Einstellwerte r Solltemperaturen ändern
rdieTemperaturprofile dereinzelnenProgrammekannzwischen
dreiTemperaturwertenausgewähltwerden:Komforttemperatur,Ab-
senktemperaturund Frostschutztemperatur.
DieseTemperaturwertesindabWerkbereitsvorprogrammiert.Sie
könnendieseauchnachIhrenWünschenändern.
5.3 Programm P3
5.3.1 Übersicht Menü "Programm"
4. WählenSieaus,obSiewährenddereingestelltenZeitdieKom-
forttemperatur, dieAbsenktemperaturoder dieFrostschutztem-
peraturhabenchten.BestätigenSiemitderOK-Taste.
5. DasFerienprogrammistnunprogrammiertundwirdzumeinge-
stelltenStart-Zeitpunktaktiviert.
6. StellenSiedenDrehschalteraufdasgewünschteProgramm
zurückundschließenSie den Klappdeckel.
7. WährenddasFerienprogrammaktivist,zeigtdasDisplaydie
Solltemperatur unddieTextzeile
Ferien
an.
1. ÖffnenSiedenKlappdeckelundstellenSiedenDrehschalterin
Stellung MENU.
2. WählenSiemitdenTasten oder denEintrag
Solltemp
.
BestätigenSiemitderOK-Taste.
3. DasDisplayzeigtzuerstdieKomforttemperaturan.
ÄndernSienacheinandermitdenTasten oder dieKomfort-
temperatur, die AbsenktemperaturunddieFrostschutztempera-
tur. JedeEinstellungmitderOK-Tastebestätigen.DieAnzeige
springtautomatischweiter.
4. NachderFrostschutztemperaturistdieEinstellungderSolltem-
peraturenabgeschlossen.DasDisplay zeigt
Ende
undspringt
nach3Sek. automatisch zurück.
5. StellenSiedenDrehschalteraufdasgewünschteProgrammund
schließenSie den Klappdeckel.
MENU
SOLLTEMP
Service
Ferien
PROGRAMM
Uhr/Datum
OK
Neu
Abfragen
Loeschen
Ende
siehe5.3.2
siehe5.3.3
siehe5.3.4
5. The holiday program is now programmed and is activated at the
set start time.
6. Reset the rotary switch to the desired program and close the
hinged cover.
7. While the holiday program is active, the display shows the target
temperature and the text line holiday.
Note: Checking, clearing or cancelling a holiday program is
described in section 4.8.
5.2 Changing the Settings for Target
Temperatures
For the temperature profiles of the individual programs, you can
choose between three temperature values: Comfort, lower and
antifreeze temperature.
These temperature values are programmed ex works. You can
change these according to your wishes.
1. Open the hinged cover and turn the rotary switch to the MENU
setting.
2. With the buttons or , select the entry target temp. Confirm
with the OK button.
3. The display first shows the comfort temperature.
With the buttons or , change the comfort, lower and anti-
freeze temperature one after the other. Confirm each setting with
the OK button. The display changes automatically.
4. After having set the antifreeze temperature, the setting of the target
temperatures is completed. The display shows end and automatically
changes back after 3 seconds.
5. Turn the rotary switch to the desired program and close the
hinged cover.
The menu target temperature is defined by
• 3 Comfort level: Comfort 1 (20 °C), Comfort 2 (18 °C),
Comfort 3 (22 °C),
• 2 Lower level: Lower 1 (17 °C), Lower 2 (15 °C) and
• 1 Frost protection level (Frost 6 °C).
If the target temperature is set to 30 °C, the symbol appears in the display
(thermostat valve). The room temperature is controlled only by the thermostat
valve. The optimising function cannot be set.
5.3 Program P1, P2, P3
5.3.1 Overview “Program” menu
see 5.3.2
see 5.3.3
see 5.3.4
Like P3, programs P1 and P2 are freely selectable.
If restore is selected (programs P1 and P2 only), the programs are reset to
factory settings at the rotary switch. If there is no available space in the
memory, the message full appears in the display.
A total of 32 feely dividable memory locations are available for all 3 programs.
MENU
SOLLTEMP
Service
Ferien
PROGRAMM
Uhr/Datum
OK
Neu
Abfragen
Loeschen
Ende
new
check
clear
restore
end
target temp
clock/date
program
holiday
service
23 ENGLISH
5.3.2 Creating a new temperature profile P3
5.3.3 Checking the temperature profile P3
5.3.4 Clearing the temperature profile
HOUR
16:00
MINUTE
16:30
New Free
21
Mo-Fr
Sa/Su
Daily
3
sec.
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
Sunday
Lower
Comfort
END
Single day
Displayofthefree
memoryareas
OK
OK
OK
OK
OK
OK
3sec.
backto
NEW
OK
BypressingtheOK or button,all
switchtimesof thedayaredis-
playedoneaftertheother.Once
thelastswitchtimeisreached,the
switchtimesofthenextdayaredis-
playedetc.
CHECK
7654321
PROG
6:00
0
3
69
12
15
18
21
24h
21 . 0 C
END
3sec.
Empty
noprogramstoredin memory
backto
Program
see5.3.1
OK
OK
backto
Program
see5.3.1
CLEAR Single All END
backto
Single
see
5.3.5 see
5.3.6
OK
5.3.2 Creating a new temperature profile P1, P2, P3
Display of the free
memory areas
5.3.3 Checking the temperature profile
5.3.4 Clearing the temperature profile
no program stored in memory
By pressing the OK or button, all
switch times of the day are displayed
one after the other. Once the last switch
time is reached, the switch times of the
next day are displayed etc.
back to
back to
back to
back to
see 5.3.2
see 5.3.1
see
5.3.5
see
5.3.6
24
ENGLISH
5.3.5 Displaying individual switch times and clearing them
5.3.6 Clearing all switch times
Theswitchtimesaredis-
playedoneaftertheother.
Displaynextswitchtime
with .
Single
Empty
7654321
PROG
6:00
0
3
69
12
15
18
21
24h
21 . 0 C
noprogramstored inmemory
7654321
PROG
6:00
0
3
69
12
15
18
21
24h
Loeschen
END
Theswitch timeis
clearedandthenext
switchtime is displayed.
3sec.
Displayoftheswitchtime
Inordertoclearthe
displayedswitchtime,
press the OK button.
OK
backto
Program
see5.3.1
OK
backto
Program
see5.3.1
OK OK
1. Displaying the switch
times
2. Clearing the desired
switch times
Clear
All
Empty
noprogramstoredinmemory
Confirm
Inordertocancelthe
clearingprocess,press
the ESC button.
backto
Program
see5.3.1
OK OK
OK
backto
Program
see5.3.1
5.3.5 Displaying individual switch times and clearing them
1. Displaying the switch
times
2. Clearing the desired
switch times
5.3.6 Clearing all switch times
no program stored in memory
In order to clear the dis-
played switch time, press
the OK button.
The switch time is
cleared and the next
switch time is displayed.
The switch times are dis-
played one after the other.
Display next switch time
with .
no program stored in memory
back to
see 5.3.1
back to
see 5.3.1
back to
see 5.3.1
back to
see 5.3.1
In order to cancel the clea-
ring process, press the ESC
button.
25 ENGLISH
5.4 Service Settings
5.4.1 Overview "Service" menu
5.4.2 Selecting the display type
MENU
TARGET TEMP
Service
Holiday
PROGRAM
Clock/Date
OK
Display
Language
Wall c omp
Control
End
see5.4.2
see5.4.3
see5.4.4
see5.4.5
Selectthedisplay typewiththe button or .
Confirmwith the OK button.CancelwithESC.
Display Display
3
OK OK
Rotaryswitchposition
P1,P2orP3 Rotaryswitch position
Displaytype Displaytype
1234512345
Time T T N N
Targettemp. N NT NN
Actualtemp. N NTN N
Programname TTTTT
Table:Overviewof the informationshown inthe displayfordifferent
displaytypes.
7654321
PROG
6:00
0
3
69
12
15
18
21
24h
21 . 0 C
T=text line
N=numericaldisplay
Note: Thefactorysettingishighlightedgreyinthetable.
5.4 Service Settings
5.4.1 Overview “Service” menu
T = text line
N = numerical display
Select the display type with the button or .
Confirm with the OK button. Cancel with ESC.
Note: The factory stetting is highlighted grey in the table
5.4.2 Selecting the display type
Table: Overview of the information shown in the display for different displays
types.
display
language
wall comp
control
pump protect
optimisation
shock delay
op hour reset
password
target temp
clock/date
program
holiday
service
see 5.4.2
see 5.4.3
see 5.4.4
see 5.4.5
etc.
26
ENGLISH
5.4.5 Adjusting the controller behaviour
Control Hys t contro l P d contro l END
Amplitude
0.2
o
C
Period
10
Hysteresis
0.3
o
C
Offset
0.3
o
C
Setwithbuttons
or :
0.2°C ... 5.0°C
5...30
0.1°C...0.2°C
END
orautom.
after6sec.
OK
OK
OK
OK OK
OK
OK
OK
back to
Service
see5.4.1
Setwithbuttons
or :
0.2°C...1.0°C
back to
see 5.4.1
5 … 30
0.1°C ...5.0°C
Set with buttons
or :
0.2°C ...5.0°C
back to
or autom.
after 6 sec.
see 5.4.1
5.4.3 Selecting the language
Select the language with the buttons or . Confirm with the OK button.
Cancel with ESC.
5.4.4 Setting the wall compensation
In case of unfavourable conditions at the installation site (installation at the
exterior wall, chimney, etc.), there may be deviations in temperature between
the temperature measured by the thermostat and the actual room temperature.
This difference in temperature can be compensated with the wall compensation by
setting an offset value.
Example: The difference between the measured and the controlled temperature
is 2 °C, i.e. the room temperature is regulated 2 °C too
high: Offset value –2 °C.
Offset value adjustable from –3 °C ... +3 °C. Setting with or . Confirm the
value with OK. Cancel with ESC.
5.4.5 Adjusting the controller behaviour
With suitable heating systems the PD controller is characterized by a short set-
ting time, scarce maximum overshooting and therefore a high control accuracy.
With over or under engineered heating systems a hysteresis controller is cha-
racterized by scarce shift frequency and small temperature deviations.
Characteristics of the PD controller
Characteristics of a hysteresis controller
Set with buttons
or :
0.2°C ...1.0°C
deutsch
english
francais
italiano
espanol
nederlands
portugues
0,1 °C ... 5,0 °C
27 ENGLISH
5.4.6 Pump protection
Pump protection is not activated in the factory. It can, however, be switched on in
the “Service” pump protect menu and then becomes active from 12.00 to 12.01
hrs.
5.4.7 Optimisation
If the optimisation function (1-60 min.) is switched on, the thermostat calculates
the ideal switching time for toggling between lower and comfort mode.
5.4.8 Shock delay
To save energy the thermostat switches off the heating for 4-15 min. by a shock
delay (in the event of a sudden drop in temperature) depending on the height of
the drop in temperature (ventilation etc.). You can switch off shock delay by pres-
sing any key (excluding the Info key) or switching the rotary knob.You can
activate or deactivate the shock delay in the “Service” menu.
The heating error message, for example, will appear if the actual temperature
does not increase after 1 hour.
5.4.9 Reset operating hours
The op hour reset function in the "Service” menu indicates the number of hours
during which the device has been switched on.
The operating hours are requested using the Info key and reset in the "Service”
menu.
5.4.10 Enter password
password appears in the "Service” menu.After confirming with OK, you can
enter the 4-digit code. Confirm each figure with OK.
The password can also be changed or cleared.
Set the rotary switch to Frost and hold down for 5 sec. pressing the OK
and ESC keys at the same time. The password has been cleared.
Once you have entered the password in the "Service” menu, you can select only
the "Display” and "Language” submenus; the entered code is required to access
all other items.
Example 1 (Comfort mode):
The setting is 10 minutes per °C at a room temperature of 17 °C.
However, room temperature should reach 20 °C by 7.00 hrs. The 7.00 hrs switchover
to comfort mode will occur at 6.30 hrs.
7.00 - 3 x 10 min. = 6.30 hrs.
Example 2 (Lower mode):
The system should be regulated to target temperature (–1 °C) ) during optimisati-
on time and before lower mode.
At 6.00 hrs, we have a room temperature of 15 °C (24 °C). ). At 22.00 hrs, the tem-
perature should be 17 °C.
24 °C - 17 °C = 7 °C x 10 = 70 minutes
22 hrs - 70 hrs = 20.50 hrs
From 20.50 hrs onwards, the system is regulated to 23 °C.
o
optimisation optimisation
10
o
password password
0- --
28
ENGLISH
27 ENGLISH
5.5 Time/Date and Summer/Winter Time
OK
MENU
Service
TARGET TEM P
CLOCK/DATE
PROGRAM
HOLIDAY
Hour Day With s/w
OK
USA/CAN
SF/GR/TR
Gb/P
Europe
OK
OK
END
End
No su/wi
Free
OK
Setting the time and date:
hour,minute,year,month,day.
Descriptionseepage18.
Month su
03:01
OK
Week su
03:02
Hour
02:00
Month wi
10:00
OK OK
Week w i
10:02
OK
OK
END
backto
Clock/Date
Startofsummertime:
Month Weekend within
month Hourforchangeover:
e.g. from 2 a.m. to
3a.m.
Startofwintertime:
Month Weekendwithinmonth
OK
Note: Timeforchangeovertowintertimeistaken
fromsummertime,e.g.backfrom3a.m.to2a.m.
OK
3sec.
5.5 Time/Date and Summer/Winter Time
Setting the time and date:
hour, minute, year, month, day.
Description see chap. 4.4.
Start of summer time:
Month Weekend within
month
Weekend within month
Hour for changeover:
e.g. from 2 a.m. to
3 a. m.
Start of winter time:
Month
Note: Time for changeover to winter time is taken from sum-
mer time, e.g. back from 3 a.m. to 2 a.m.
back to
29
28
ENGLISH
6 Maintenance and Repair
Withtheexceptionofaregularreplacementofthebatteriesforthe
RAMSES®811 top, the room thermostatsaremaintenance-free.
Onlycleanthedevice withadry or slightlydamp,soft and lint-free
cloth.Theinteriorofthedevicemustremainfreefromwater.
OnlyRAMSES®811 top:
Replacethetwobatteriesatregularintervalsevery1.5years.Only
use new1.5 V batteries of the typeAA, Alkaline.Nevermixold and
newbatteries,asoldbatteriescanleak.
7 Disposal
7.1 Disposal of Batteries
Usedbatteriesmustbedisposedofaccordingtothe nationalregula-
tionswithregardtotheenvironment(e.g.atspecialbatterycollection
outlets).Neverthrowusedbatteriesoutwith your usualrubbish.
7.2 Disposal of the Device
Attheendofitslife,theroomthermostatmustbedismountedprofes-
sionallyanddisposedofaccordingtothenationalregulationswithre-
gardtotheenvironment.
Incaseof doubts,pleasecontactthemanufacturersrepresentative
inyourcountry.Contactdetailscanbefoundat the backofthisman-
ual.
8 Technical Data
Control type: RS type 2B acc. to EN 60730-1:1991
Contact: Change-over contact, potential-free,
protectivelowvoltage.
Max.6A/250V~,min.1mA/5V
Accuracy: ± 1sec. per day at 20°C
Controlaccuracy: ±0.2K
Temperature meas. range: 0°C to 50°C, resolution 0.C
Temperature setting range: 6°C to 30°C in increments of 0.C
Controlperiod: 5to30min.(PDcontrol)
Control lock-in range: ± 0.2 K to± 5K (PD control)
Switching hysteresis: ± 0.2 K to±1.0 K (hysteresis control)
Memoryspaces: 22temperaturechanges,programmable
for Mo-Fr,Sa-Su, eachday orforindivid-
ualdays.
Class of protection: II according to EN 60730-1
Type of enclosure: IP 20 according to EN 60529-1
OnlyRAMSES®812 top
Operatingvoltage: 230V~±10%;240V~ + 6%,-14 %
50to 60Hz
Powerreserve: 5hours
OnlyRAMSES®811 top
Batteries: 2xalkalinebatteries1.5V, typeAA
Powerreserveduring
batteryreplacement: 10minutes
6 Maintenance and Repair
With the exception of a regular replacement of the batteries for the
RAMSES®831 top, the room thermostats are maintenance-free.
Only clean the device with a dry or slightly damp, soft and lint-free cloth.
The interior of the device must remain free from water.
Only RAMSES®831 top:
Replace the two batteries at regular intervals every 1.5 years. Only
use new 1.5 V batteries of the type AA, Alkaline. Never mix old and
new batteries, as old batteries can leak.
7 Disposal
7.1 Disposal of Batteries
Used batteries must be disposed of according to the national regulations with
regard to the environment (e.g. at special battery collection outlets). Never throw
used batteries out with your usual rubbish.
7.2 Disposal of the Device
At the end of its life, the room thermostat must be dismounted professionally and
disposed of according to the national regulations with regard to the environment.
In case of doubts, please contact the manufacturer’s representative in your country.
Contact details can be found at the back of this manual.
8 Technical Data
Control type: RS type 1B acc. to EN 60730-1:2001
Contact: Change-over contact, potential-free,
protective low voltage.
Max. 6A / 250 V~, min. 1 mA / 5V
Accuracy: ± 1 sec. per day at 20 °C
Control accuracy: ± 0.2 K
Temperature meas. range: O °C to 50 °C, resolution 0.1 °C
Temperature setting range: 6 °C to 30 °C in increments of 0.2 °C
Control period: 5 to 30 min. (PD control)
Control lock-in range: ± 0.2 K to ± 5 K (PD control)
Switching hysteresis: ± 0.2 K to ± 1 0 K (hysteresis control)
Memory spaces: 22 temperature changes, programmable
for Mo-Fr, Sa-Su, each day or for individual
days.
Class of protection: II according to EN 60730-1 with correct
installation
Type of enclosure: IP 20 according to EN 60529-1
Only RAMSES®832 top
Operating voltage: 230 V~ ± 10 %; 240 V~ + 6 %, -14 %
50 to 60 Hz
Power reserve: 5 hours
Only RAMSES®831 top
Batteries: 2 x alkaline batteries 1.5 V, type AA
Power reserve during
battery replacement: 10 minutes
30
91 NEDERLANDS
Environmental information
The equipment that you bought has required the extraction and use of natural
resources for its production. It may content hazardous substances for the health and
the environment. In order to avoid the dissemination of those substances in our
environment and to diminish the pressure on the natural resources, we encourage
you to use the appropriate take-back systems. Those systems will reuse or recycle
most of the materials of your end life equipment in a sound way. The crossed-bin
symbol invites you to use those systems. If you need more information on the
collection, reuse and recycling systems, please contact your local or regional waste
administration. You can also contact us for more information on the environmental
performances of our products.
Information relative à l’environnement
La production de l’appareil que vous avez acheté a nécessité l’extraction et l’utilisa-
tion de ressources naturelles. Il peut contenir des substances dangereuses pour la
santé et l’environnement. Pour éviter la dispersion de ces substances dans notre
environnement et réduire la consommation des ressources, nous vous encourageons
à utiliser les systèmes de collecte appropriés lorsque vous devrez vous débarrasser
de votre appareil en fin de vie. Ces systèmes permettront de réutiliser ou recycler de
manière saine la plupart des matières. Le symbole de la poubelle barrée vous invite
à utiliser ces systèmes de collecte. Si vous désirez des informations complémentaires
sur ces systèmes de collecte, de remploi et de recyclage, prenez, s’il vous plaît,
contact avec l’administration locale ou régionale de gestion des déchets.
Milieu-informatie
Het apparaat dat u heeft aangekocht noodzaakte de extractie en het ge-bruik van
natuurlijke rijkdommen voor zijn productie. Het kan gevaarlijke stoffen voor de
gezondheid en het milieu bevatten. Dit product moet worden ingeleverd bij een
aangewezen, geautoriseerd inzamelpunt, bijvoorbeeld wanneer u een nieuw geli-
jksoortig product aanschaft, of bij een ge-autoriseerd inzamelpunt voor hergebruik
van elektrische en elektronische apparatuur. Bovendien werkt u door een juiste
afvoer van dit product mee aan het effectieve gebruik van natuurlijke hulpbronnen.
Het symbool van de doorkruiste vuilnisbak nodigt u uit dit verzamelsysteem te
gebruiken.Voor meer informatie over waar u uw afgedankte apparatuur kunt inle-
veren voor recycling kunt u contact opnemen met het gemeentehuis in uw woon-
plaats, de reinigingsdienst, of het afvalverwerkingsbedrijf.
Theben AG
Hohenbergstr. 32
72401 Haigerloch
DEUTSCHLAND
Tel. +49 (0) 74 74/6 92-0
Fax +49 (0) 74 74/6 92-150
Service
Tel. +49 (0) 74 74/6 92-369
Fax +49 (0) 74 74/6 92-207
hotline@theben.de
Adresses, telephone numbers etc. at
www.theben.de
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Theben RAM 831 top at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Theben RAM 831 top in the language / languages: English as an attachment in your email.

The manual is 0.76 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Theben RAM 831 top

Theben RAM 831 top User Manual - German - 18 pages

Theben RAM 831 top User Manual - Dutch - 20 pages

Theben RAM 831 top User Manual - French - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info