Continuous valve actuator CHEOPS control
theben
As of: Jul-11 (Subject to change without notice) Page 37 of 71
Continuation:
Designation
Values
Application
Function of Object 6
Increase or decrease set point
value
Determines maximum actuating
value
Sends the actual valve position
Change set point value in
increments via Object 6
Object 6 Determining the
maximum actuating actuating
value
Object 6 sends the current
valve position during the
tappet movement.
This setting is most suitable
for diagnostic operations
Designation
Values
Meaning
Transmission of maximum
actuating value
when internal actuating value
is higher than the received
Every 2 min
Every 3 min
Every 5 min
Every 10 min
Every 15 min
Every 20 min
Every 30 min
Every 45 min
Every 60 min
Object 6 will only send if all
other actuators have a smaller
actuating value
Object 6 sends its actuating
value cyclically and starts a
new calibration
Transmission of actual
valve position
Does not send
At change of 1%
At change of 2 %
At change of 3 %
At change of 5 %
At change of 7 %
At change of 10 %
At change of 15 %
Sends the new valve position
as soon as it has changed
since the last sending by the
configured amount.
At the end of positioning, the
achieved value is sent
regardless of the configured
interval.
37


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Theben CHEOPS control KNX at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Theben CHEOPS control KNX in the language / languages: English as an attachment in your email.

The manual is 0,6 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Theben CHEOPS control KNX

Theben CHEOPS control KNX User Manual - English - 1 pages

Theben CHEOPS control KNX User Manual - German - 72 pages

Theben CHEOPS control KNX User Manual - German - 1 pages

Theben CHEOPS control KNX User Manual - Dutch - 76 pages

Theben CHEOPS control KNX User Manual - French - 74 pages

Theben CHEOPS control KNX User Manual - French - 1 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info