472739
3
Zoom out
Zoom in
Previous page
1/4
Next page
- 1 -
User Manual of Thermo-Timer ET01
The ET01 Thermo-Timer is a very versatile product that can control both temperature
and timer independently and in cohesion. Its sophisticated internal program allows users
many different combinations for various applications. The external water proof
temperature probe with cable allows temperature measurement in remote environment.
Following is the description of the operation of the ET01.
LCD display
A) Thermo-Timer in Timer mode icon
B) Thermo-Timer in ON state
C) Thermo-Timer in OFF state
D) Thermo-Timer in Temperature mode icon
E) Timer/Temperature control pair number
F) Timer/Temperature control disable
G) C/F icon
1. Power On and normal Display Modes
When an AAA battery is first inserted, all LCD display segments will be on for a brief
period then the display jumps to show clock time and an icon INT (means control is
interrupted or disabled). By pressing the MODE key once, the display can also be
diverted to show the temperature value which is the temperature measured by the probe.
The display can therefore be toggled between time and temperature by pressing the
MODE key.
- 2 -
2. Clock Set
In the clock mode, press the SET key once, an icon C will shown blinking. This is the set
clock mode. Hours and minutes values can now be entered by pressing the keys h/ and
m/. Press SET key once to return to normal clock display.
3. Modes of Operation
There are in total three control modes of operation in ET01 selectable by the user to fit
his application requirement.
Thermo mode
Timer mode
Thermo-Timer mode
Each mode is independent of the other and at each time only one mode can be in
operation. Activate one mode means automatically disabling the other previously active
mode.
Mode 1 – Temperature control mode – symbol is ( )
To enter this mode, in normal clock or temperature display mode, press SET key once to
see the flag C blinking. Now press the MODE key once to see the display changes to set
temperature value mode which shows 18 ° C as the default value. A thermometer flag
is shown blinking denoting the user he is in temperature set mode. The temperature value
can now be changed up or down by the h/ or the m/ keys. The settable range is 40° C
to 0° C. After the desired value is set, press SET key once to leave the temperature set
mode and returns to normal temperature display mode. The thermometer flag is now
showing steadily. If the control temperature set value is higher than the temperature
measured by the probe, the flag ON will be shown to inform the control output is now
active. Otherwise the INT flag is maintained. The temperature control activity can be
temporarily suspended by first entering the set temperature mode, then press the Manual
Override key once, a cross flag will appear to inform the temperature control action is
now suspended.
- 3 -
Mode 2 - Timer Control Mode symbol is ( )
To enter this mode, in normal clock or temperature mode, press SET key once to see the
flag C blinking. Now press the MODE key twice to enter the Timer Control Mode. The
timer symbol is shown blinking together with the value of the first ON timer value
which is shown in the following diagram if no value has been entered before:
Use keys h/ and m/ to enter the hours and minutes of the ON time for the first timer
pair. Press SET once to enter the value of OFF (INT) time for the first pair. In like
manner the ON time and OFF time of the three timer pairs can be entered.
Each ON and OFF times can be suspended by using the Manual Override key during time
setting. A symbol is shown to denote this condition.
The control output is activated each time the real clock time matches the set timer time.
This means three time periods can be controlled for ON and OFF.
Mode 3 - Thermo-Timer mode - symbols is ( )
This is a combined operation mode of mode 1 and mode 2. In this mode three time pairs
with three different temperature values can be set so that three temperatures in three
periods of time can be controlled.
To enter this mode, press SET key once in normal mode to see the blinking C. Now press
the MODE key three times to see the flags and . The timer flag is blinking to notify
that the timer value can be set. After setting the ON time, press SET key to enter
temperature value set where the flag is blinking. Enter the desired temperature value
then press SET key again to set the OFF time. In like manner all three pairs of timers and
temperature values can be set. All values can be suspended by using the Manual Override
key as before.
- 4 -
Manual Override Function
During operation, the output condition of the ET01 can be altered by press the Manual
Override key once, if the flag ON is shown then it will change to INT and blinking. If the
INT is on, then it will switch to ON and blinking.
Notes of Importance:
1. The product can be completely reset by press down SET and MODE together and
release. It will return to the POWER ON condition and all set values will be lost.
2. If the display seems dim then it is time to change the battery. All set values will
be lost after battery change and needs to be re-entered
3. The temperature probe is protected by a metal shield and plastic cover. Make sure
they are not damaged so that water proofing is not longer possible. Store the
probe and cable inside the compartment at the bottom of the ET01 if not used.
4. Maximum probe length is 1 meter and control range is from 20° C to 40° C.
Victorsure Limited - October/2003
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for TFA thermo-timer 16A at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of TFA thermo-timer 16A in the language / languages: English as an attachment in your email.

The manual is 0,05 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of TFA thermo-timer 16A

TFA thermo-timer 16A User Manual - German - 1 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info