539597
34
Zoom out
Zoom in
Previous page
1/34
Next page
34
Technische Daten
Sensoren (Supply=6.0V, Ta=23°C) und Sensor Hauptstation
(Supply=3.0V, Ta=23°C)
RF Funkübertragungsfrequenz 433 MHz
RF Funkübertragungsdistanz 100 Meter maximal ( Sichtreichweite )
Barometrischer Luftdruckmessbereich 500 hpa to 1100hpa ( 14.75 inHg to 32.44 inHg ),
(Auf Meeresspiegel ) ( 374.5 mmHg to 823.8 mmHg )
Höhenmessbereich -200m to +5000 m ( -657 ft to 16404 ft )
Barometrische Druckauflösung 0.1 hpa ( 0.003 inHg, 0.08 mmHg )
Barometrische Luftdruckmessunggenauigkeit +/- 5 hpa ( 0.015 inHg, 0.38 mmHg )
Außentemperatur-Messbereich -40°C to80°C ( -40°F to 176°F )
Innentemperatur-Messbereich -9.9°C to 60°C ( 14.2°F to 140°F)
Betriebstemperatur 0°C to 50°C ( 32°F to 122°F)
Außentemperaturbereich -20°C to 60°C( -4°F to 140°F)
Temperaturgenauigkeit +/- 1°C or +/- 2°F
Temperaturauflösung 0.1°C or 0.2°F
Luftfeuchtigkeitsanzeige 0% to 99%
Luftfeuchtigkeitsanzeigegenauigkeit +/-5%
Luftfeuchtigkeits-Auflösung 1%
Übertragungszyklus
Thermo-Hygro-Sensor 47s
Regenmesser 183s
Windmesser 33s
Sonnenaufgang-Sonnenuntergang
Anzeigegenauigkeit +/- 3min ( Innenbreite +/- 50° )
Wind Richtungsanzeige 16 Positionen
Wind Richtungsanzeigengenauigkeit +/-11.25°
Wind Richtung Auflösung 22.5°
Wind Richtung Ausgangspunkt 3mph
Wind Geschwindigkeitsanzeige 0 to 199.9mph
(199.9 Km/h, 173.7 Knoten, 89.3 m/s)
Wind Geschwindigkeit-Genauigkeit +/- ( 2mph + 5% )
Wind Geschwindigkeit-Ausgangspunkt 3mph
Wind/Gust Speed Disply Update Interval 33 Sekunden
Windböenintervalle 11 Sekunden
1h/24h/Vortag Niederschlagsmessung 0.0 to 1999.9 mm ( 78.73 inch )
Letzte Woche/Letzter Monat-Messung 0 to 19999 mm ( 787.3 inch )
Innentemperaturübertragungszyklus 10s
Raumlufttemperaturübertragungszyklus 10s
CD-ROM (Englisch und Deutsch)
USB Kabel 2 m (6ft)
System: Windows ‘98 oder aktueller
34


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for TFA Sinus 35.1095 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of TFA Sinus 35.1095 in the language / languages: German as an attachment in your email.

The manual is 1,08 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of TFA Sinus 35.1095

TFA Sinus 35.1095 User Manual - English - 31 pages

TFA Sinus 35.1095 User Manual - French - 32 pages

TFA Sinus 35.1095 User Manual - Italian - 33 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info