Mould RADAR thermo-hygrometer
4. Functions
Indoor temperature
Relative air humidity indoor
Maximum and minimum values
Dew point
24-hour mould radar
Audible and visual alarm function
5. For your safety
This product is exclusively intended for the field of application described above. It should
only be used as described within these instructions.
Unauthorized repairs, modifications or changes to the product are prohibited.
This product is not be used for medical purpose or for public information, it is only intend-
ed for home use.
Caution!
ƽ
Risk of injury:
Keep this instrument and the batteries out of the reach of children.
Batteries must not be thrown into a fire, short-circuited, taken apart or recharged. Risk of
explosion!
Batteries contain harmful acids. Low batteries should be changed as soon as possible to
prevent damage caused by leaking.
Never use a combination of old and new batteries together, or batteries of different types.
Wear chemical-resistant protective gloves and glasses when handling leaking batteries.
ƽ
Important information on product safety!
Do not place your product near extreme temperatures, vibrations or shocks.
Protect it from moisture.
6. Elements
A: Display:
A 1: 24-hour mould radar
A 2: Indoor temperature (°C/°F) and humidity / Maximum and minimum values / Dew point
A 3: Smiley for the comfort level
Mould RADAR thermo-hygrometer
B: Front - Sensor buttons:
B 1: min/max button
B 2: Taupunkt (Dew point) button
C: Back - Slide switch
C 1: Alarm sound (Speaker symbol)
C 2: Animation (Arrow symbol)
D: Housing:
D 1: Suspension device
D 2: Battery compartment
D 3: Switch Taupunkt / dew point (inside the battery compartment)
D 4: Holder for the support
D 5: Warning LED when risk of mould
7. Getting started
Remove the protective foil from the display.
Open the battery compartment and remove the battery insulation strip.
The device will alert you with a beep and all LCD segments will be displayed for about
two seconds.
The indoor temperature, the humidity and the corresponding smiley symbol appear on
the display.
The unit is ready for use.
Attention: Do not attach the support until the settings for the animation and alarm func-
tion are complete.The two slide switches are covered by the support.
8. Operation
8.1 Display of the 24 hours mould radar
The device measures the relative humidity every 30 seconds and calculates from these
values every 10 minutes the average value.
The innovative mould radar display shows graphically on a 24 hour timeline the maximum
averages that were reached.
The time “0h” represents the value of the current hour, “-1” the last hour “-3” of the past
2-3 hours, "-6" of the past 4-6 hours, “-12” of the past 7 -12 hours and “-24” of the past
13-24 hours.
The relative humidity values are shown in a grid of 10 from 15 to 85%. More than 65%
RH means risk of mould.
TFA_No. 30.5032_Anleitung_05_14 28.05.2014 13:42 Uhr Seite 7
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for TFA 30.5032 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of TFA 30.5032 in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 0,25 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info