AVENUE PLUS – Digital garden thermometer with solar lighting
1716
Please consider when choosing a location that the solar panel needs at least 8-10 hours of
light per day to guarantee a long-term sufficient power supply. Attention: Direct sunshine
falsifies the measurement. The thermometer is provided with a light sensor to turn on the
light automatically at dark between 5 and 9 o’clock and 18 and 23 o’clock. Avoid the close-
ness of artificial light (like: street lighting).
With the ECO slide it is possible to turn the time controlled illumination on (left) or off (right)
If the ECO mode is not active the illumination will turn on automatically as soon as the light
sensor indicates darkness.
When the battery symbol appears on the display, the voltage of the rechargeable battery is
low and the back light function can be temporarily disabled, until the power supply by the
solar panel is sufficient again.
Press the plate firmly into the ground.
Mount the rod and put it into the ground passing through the hole in the middle of the plate.
Fix the thermometer on the rod and turn the solar panel (rotatable 180°) to the direction
where it receives the highest light supply.
6. Care and maintenance
For best function keep the solar panel always clean. Clean it with a soft cloth and maybe a lit-
tle glass- or display cleaner. Do not use solvents or scouring agents.
Remove the battery if you do not use the product for a long period of time.
6.1 Battery replacement
Please change the 1.5 V AA battery when the display becomes weak.
Use alkaline batteries only. Observe correct polarity.
7. Troubleshooting
Problem Solutions
No indication Ensure correct polarity, when inserting the battery
Incorrect indication Change the battery
No illumination Make sure that no objects cover the solar panel
(see point 5.7)
No DCF reception Press the button for 6 seconds and start the initializa-
tion manually
Activate DCF reception (see point 5.2e)
AVENUE PLUS – Digital garden thermometer with solar lighting
e. Press the MODE button again. If you wish to deactivate the DCF reception, press the +1
button. "DCF enable" disappears.
f. Press MODE button again to return to normal mode.
If no DCF reception symbol is displayed, manual clock setting is possible at any time. Follow
the steps a. to f. when the display shows the time (switch to B or C position).
The device will automatically quit the setting mode if no button is pressed for 15 seconds.
Once the DCF time signal is successfully received and the DCF reception is activated (DCF
enable is displayed), the manually set time is overwritten.
5.3 °C/°F display change
When the display shows the current temperature, press +1 button to change between °C or
°F as temperature unit. The time will change from 24 to 12-hour system at the same time.
In the 12-HR system AM (before noon) or PM (after noon) appears on the display.
5.4 Display mode selection
Switch position A: Current temperature (display: >)
Switch position B: Current temperature and time alternately (display: >>)
Switch position C: Current temperature, highest/lowest temperature and time alternately
(display: >>>)
5.5 Maximum and minimum temperatures
The maximum and minimum values are automatically reset: The maximum temperature at
8:00 and minimum temperature at 20:00 o'clock. To use this function, the actual time must
be received via DCF or set manually.
Auto Reset flashes on the display.
5.6 Temperature probe
The silver pin is the temperature probe. Please take care of it and do not break it. The tem-
perature probe has no adjusting function. It only measures the temperature.
5.7 Backlight and fixing
The supplied battery will be recharged in an environmentally friendly manner by the solar
panel.
TFA_No. 30.2030_Anleit_10_16 13.10.2016 11:42 Uhr Seite 9
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for TFA 30.2030 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of TFA 30.2030 in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 0,23 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info